Description
2.2 Technical characteristics and ambient conditions
1PH808/1PH810 main motors
Operating Instructions, 04/2017, 610.48004.40f
27
2.2.3
Ambient conditions
The following temperature ranges apply to motors with forced ventilation.
●
Permissible temperature range in operation: T = -15 °C to +40 °C
●
Permissible temperature range during storage: T = -20 °C to +70 °C
Under conditions other than those specified above (ambient temperature > 40 °C or
installation altitude > 1000 m above sea level), the permissible torques/powers must be
determined from the following table. Ambient temperatures and installation altitudes are
rounded off to 5 °C or 500 m respectively.
Table 2- 1
Power derating as a function of the installation altitude and ambient temperature
Installation
altitude above
sea level [m]
Ambient temperature in °C
< 30
30 - 40
45
50
55
1000
1.07
1.00
0.96
0.92
0.87
1500
1.04
0.97
0.93
0.89
0.84
2000
1.00
0.94
0.90
0.86
0.82
2500
0.96
0.90
0.86
0.83
0.78
3000
0.92
0.86
0.82
0.79
0.75
3500
0.88
0.82
0.79
0.75
0.71
4000
0.82
0.77
0.74
0.71
0.67
●
Adapt the motor torque or power to the converter. Observe the operating instructions of
the converter.
Note
Unsuitable installation locations
The motors are not suitable for operation
•
in salt-laden or corrosive atmospheres
•
outdoors
2.2.4
Degree of protection
The motors with forced ventilation (1PH808 or 1PH810) have degree of protection IP55.
The water-cooled motors (1PH808 or 1PH810) have degree of protection IP65.
Содержание SIMOTICS M-1PH8
Страница 1: ......
Страница 2: ......
Страница 8: ...Introduction 1PH808 1PH810 main motors 8 Operating Instructions 04 2017 610 48004 40f ...
Страница 12: ...Table of contents 1PH808 1PH810 main motors 12 Operating Instructions 04 2017 610 48004 40f ...
Страница 40: ...Description 2 4 Structure 1PH808 1PH810 main motors 40 Operating Instructions 04 2017 610 48004 40f ...
Страница 118: ...Commissioning 6 6 Cooling 1PH808 1PH810 main motors 118 Operating Instructions 04 2017 610 48004 40f ...
Страница 124: ...Operation 7 2 Non operational periods 1PH808 1PH810 main motors 124 Operating Instructions 04 2017 610 48004 40f ...
Страница 144: ...Maintenance 8 2 Corrective maintenance 1PH808 1PH810 main motors 144 Operating Instructions 04 2017 610 48004 40f ...
Страница 147: ...Spare parts 1PH808 1PH810 main motors Operating Instructions 04 2017 610 48004 40f 147 Figure 9 1 Spare parts example ...
Страница 148: ...Spare parts 1PH808 1PH810 main motors 148 Operating Instructions 04 2017 610 48004 40f ...
Страница 185: ......
Страница 186: ......