Mechanical mounting
5.4 Mounting the stator with the spindle housing
1FE1 synchronous built-in motors
Hardware Installation Manual, 12/2016, 610.43000.40b
77
Examples for the vertical mounting of the spindle housing
Example A: Vertical mounting of the stator in the spindle housing
Use this joining procedure when the connection cables exit from the larger cooling jacket
diameter.
Procedure
1
Stator with cooling jacket
5
Cable entry
2
O-ring seals (four)
6
Connection cables
3
Axial stop
7
Spacing sleeves (example)
4
Spindle housing
8
Lifting lug / eyebolts
Figure 5-11 Vertical mounting of the stator in the spindle housing, steps 1, 7 and 8
1.
Place the spindle housing at the axial stop.
2.
Remove the lifting lug and the eyebolts.
3.
Check that the four O-ring seals are fitted correctly.
4.
Fasten the eyebolts, possibly with spacer sleeves, to the cooling jacket.
5.
Take the stator at the lifting lug.
6.
Position the stator so that you can route the connection cables through the cable gland of
the spindle housing or the bearing shield later.
Содержание Simotics M-1FE1 Series
Страница 1: ......
Страница 2: ......
Страница 8: ...Introduction 1FE1 synchronous built in motors 8 Hardware Installation Manual 12 2016 610 43000 40b ...
Страница 12: ...Table of contents 1FE1 synchronous built in motors 12 Hardware Installation Manual 12 2016 610 43000 40b ...
Страница 40: ......
Страница 50: ......
Страница 136: ...Operation 8 4 Stoppages 1FE1 synchronous built in motors 136 Hardware Installation Manual 12 2016 610 43000 40b ...
Страница 138: ...Service and maintenance 1FE1 synchronous built in motors 138 Hardware Installation Manual 12 2016 610 43000 40b ...
Страница 144: ...1FE1 synchronous built in motors 144 Hardware Installation Manual 12 2016 610 43000 40b ...
Страница 146: ...List of abbreviations 1FE1 synchronous built in motors 146 Hardware Installation Manual 12 2016 610 43000 40b ...
Страница 149: ......
Страница 150: ......