![Siemens Simotics HV C 1NA14544WA600AG0-Z Скачать руководство пользователя страница 72](http://html.mh-extra.com/html/siemens/simotics-hv-c-1na14544wa600ag0-z/simotics-hv-c-1na14544wa600ag0-z_operating-instructions-and-installation-instructions_379029072.webp)
8.9.4
Roller bearing faults
Damage to roller bearings can be difficult to detect in some cases. If in doubt, replace the
bearing. Use other bearing designs only after consulting the manufacturer.
Table 8-3
Roller bearing faults
↓ Bearing overheats
↓ Bearing "whistles"
↓ Bearing "knocks"
Possible causes of faults
Remedial measures
X
High coupling pressure
Align the machine more accurately.
X
Belt tension too high
Reduce the drive belt tension.
X
Bearing contaminated
Clean or replace the bearing. Check the seals.
X
High ambient temperature
Use a suitable high-temperature grease.
X
X
Insufficient lubrication
Grease the bearings as instructed.
X
X
Bearing canted
Contact the Service Center.
X
X
Insufficient bearing play
Contact the Service Center.
X Excessive bearing play
Contact the Service Center.
X
X
Bearing corroded
Replace the bearing. Check the seals.
X
Too much grease in bearing
Remove surplus grease.
X
Wrong grease in the bearing
Use the correct grease.
X Friction marks on raceway
Replace the bearing.
X Brinelling or scoring
Replace the bearing. Avoid any vibration at standstill
8.9.5
Cooling system faults
The following table shows the possible causes of and remedial measures for faults on water-
cooled machines.
Table 8-4
Cooling system faults
↓ Overheating
↓ Water leaking
Possible causes of faults
Remedial measures
X
Reduced cooling
● Check the cooling water flow, increase the amount of cooling water
if necessary.
● Clean the cooling system, e.g. by briefly increasing the cooling
water flow rate or by adding suitable cleaning agents.
X
Cooling water flow rate too low
Consult the manufacturer. If the specified cooling water quality is ob‐
served, the cooling system is maintenance-free.
X
Inlet temperature too high
Set the correct upstream temperature.
X
Cooling water supply switched off
Switch on the cooling water supply.
X
Cooling water contains too many or unsuit‐
able antifreeze and corrosion-protection
agents
Use cooling water of the agreed quality.
Operation
8.9 Faults
SIMOTICS HV C 1NA14544WA600AG0-Z
72
Operating Instructions 06/2018
Содержание Simotics HV C 1NA14544WA600AG0-Z
Страница 2: ...14 06 2018 09 34 V3 00 ...
Страница 10: ...Table of contents SIMOTICS HV C 1NA14544WA600AG0 Z 10 Operating Instructions 06 2018 ...
Страница 74: ...Operation 8 9 Faults SIMOTICS HV C 1NA14544WA600AG0 Z 74 Operating Instructions 06 2018 ...
Страница 90: ...Maintenance 9 3 Corrective Maintenance SIMOTICS HV C 1NA14544WA600AG0 Z 90 Operating Instructions 06 2018 ...
Страница 98: ...Disposal 11 4 Disposal of components SIMOTICS HV C 1NA14544WA600AG0 Z 98 Operating Instructions 06 2018 ...
Страница 100: ...Service and Support SIMOTICS HV C 1NA14544WA600AG0 Z 100 Operating Instructions 06 2018 ...
Страница 104: ...Quality documents SIMOTICS HV C 1NA14544WA600AG0 Z 104 Operating Instructions 06 2018 ...
Страница 106: ...Additional documents SIMOTICS HV C 1NA14544WA600AG0 Z 106 Operating Instructions 06 2018 ...
Страница 110: ...Index SIMOTICS HV C 1NA14544WA600AG0 Z 110 Operating Instructions 06 2018 ...
Страница 111: ......