Operation
8.1 Safety instructions for operation
Standard motors SH 63 ... 355
88
Operating Instructions, 12/2018, A5E38483075A
NOTICE
Risk of corrosion due to condensation
If the machine and/or ambient temperatures fluctuate, this can result in condensation inside
the machine.
•
If available, remove the drain plugs or drain screws to drain the water depending on the
ambient and operating conditions.
•
If available, re-attach the drain plugs or drain screws.
If the motor is equipped with drain plugs, then the water can drain away by itself.
Switching on the machine with anti-condensation heating (optional)
CAUTION
Machine overheating
Minor injury or material damage can occur if you do not observe the following:
•
If available, switch off the anti-condensation heating each time before switching on.
8.1.1
Safety instructions relating to ventilation and cooling
8.1.1.1
Safety instruction for forced ventilation (option)
Forced ventilation (optional): Type of cooling IC 416 in accordance with EN / IEC 60034-6
WARNING
Risk of burning
Operating the machine without external fan results in overheating. This may result in death,
personal injury and material damage.
•
Never commission the machine without an external fan.
Содержание SIMOTICS DP series
Страница 1: ......
Страница 2: ......
Страница 62: ...Assembly 5 4 Installing the machine Standard motors SH 63 355 60 Operating Instructions 12 2018 A5E38483075A ...
Страница 86: ...Commissioning 7 2 Switching on Standard motors SH 63 355 84 Operating Instructions 12 2018 A5E38483075A ...
Страница 98: ...Operation 8 7 Deactivating Standard motors SH 63 355 96 Operating Instructions 12 2018 A5E38483075A ...
Страница 118: ...Maintenance 9 3 Corrective maintenance Standard motors SH 63 355 116 Operating Instructions 12 2018 A5E38483075A ...
Страница 140: ...Disposal 11 6 Disposal of components Standard motors SH 63 355 138 Operating Instructions 12 2018 A5E38483075A ...
Страница 150: ......