Image 9-6
Speed encoder mounting
1. If the coupling at the speed encoder end has been separated, use removable LOCTITE
to secure the lateral stud bold or set screw when the coupling is assembled and tighten
with the correct torques.
Table 9-7
Tightening torques for mounting couplings
Thread size
Tightening torque [Nm]
M4
1.3
M5
2.6
M6
4.5
1. Check the elastic connecting link (coupling star) to ensure that it is in a good condition and
in the correct mounting position.
2. Mount the complete speed encoder.
Maintenance
9.2 Repair
SIMOTICS DC 1GH5
Operating Instructions 02/2016
97
Содержание SIMOTICS DC 1GH5
Страница 2: ...08 02 2016 10 31 V4 00 ...
Страница 12: ...Introduction 1 1 About these instructions SIMOTICS DC 1GH5 12 Operating Instructions 02 2016 ...
Страница 50: ...Assembling 5 3 Installing the machine SIMOTICS DC 1GH5 50 Operating Instructions 02 2016 ...
Страница 76: ...Operation 8 9 Faults SIMOTICS DC 1GH5 76 Operating Instructions 02 2016 ...
Страница 98: ...Maintenance 9 2 Repair SIMOTICS DC 1GH5 98 Operating Instructions 02 2016 ...
Страница 110: ...Spare Parts 10 7 Speed sensor SIMOTICS DC 1GH5 110 Operating Instructions 02 2016 ...
Страница 114: ...Service and Support SIMOTICS DC 1GH5 114 Operating Instructions 02 2016 ...
Страница 118: ...Quality documents SIMOTICS DC 1GH5 118 Operating Instructions 02 2016 ...
Страница 124: ...Checklists D 4 Inspection when the motor is running SIMOTICS DC 1GH5 124 Operating Instructions 02 2016 ...
Страница 128: ...Index SIMOTICS DC 1GH5 128 Operating Instructions 02 2016 ...
Страница 129: ......
Страница 130: ...Siemens AG Process Industries and Drives Postfach 48 48 90026 NÜRNBERG GERMANY www siemens com drives ...