● Test the rotor to see if it is running smoothly. The permissible rotor deviation on the
commutator is 0.2 mm.
● Mount the entire speed-sensor stator.
9.2.6.3
Speed sensor for construction type IM B5
Removal
The speed encoder is designed for mounting, corresponding to type of construction IM B5. It
is driven through a jaw clutch (Rotex).
If a different design is used, the installation and operating instructions of the speed encoder
manufacturer apply.
Note
Damage to the speed encoder
The speed encoder can be damaged when removing the machine. Remove the speed encoder
before removing the motor.
1. Completely unscrew the speed encoder and move it away, axially. This separates the
coupling halves axially.
2. The shaft journals or half-couplings mounted on or in the machine shaft extension must be
removed and replaced if they are damaged.
– When replacing damaged parts, such as the tolerance ring, please ensure they are
correctly arranged.
– Use LOCTITE that can be removed and suitable tools to assemble parts.
3. Release or tighten the screwed-in coupling part at the hexagon socket head screw (Allen
screw, 8mm)
Table 9-6
Recommended torques for tightening the coupling
Thread size
Torque [Nm]
M16
20
M20
30
M24
40
Installation
Firmly reattach the speed encoder that was removed. If a different design is used, the
installation and operating instructions of the speed encoder manufacturer apply.
The legend numbers in the following illustration are explained in chapter Spare parts / Speed
Maintenance
9.2 Repair
SIMOTICS DC 1GH5
96
Operating Instructions 02/2016
Содержание SIMOTICS DC 1GH5
Страница 2: ...08 02 2016 10 31 V4 00 ...
Страница 12: ...Introduction 1 1 About these instructions SIMOTICS DC 1GH5 12 Operating Instructions 02 2016 ...
Страница 50: ...Assembling 5 3 Installing the machine SIMOTICS DC 1GH5 50 Operating Instructions 02 2016 ...
Страница 76: ...Operation 8 9 Faults SIMOTICS DC 1GH5 76 Operating Instructions 02 2016 ...
Страница 98: ...Maintenance 9 2 Repair SIMOTICS DC 1GH5 98 Operating Instructions 02 2016 ...
Страница 110: ...Spare Parts 10 7 Speed sensor SIMOTICS DC 1GH5 110 Operating Instructions 02 2016 ...
Страница 114: ...Service and Support SIMOTICS DC 1GH5 114 Operating Instructions 02 2016 ...
Страница 118: ...Quality documents SIMOTICS DC 1GH5 118 Operating Instructions 02 2016 ...
Страница 124: ...Checklists D 4 Inspection when the motor is running SIMOTICS DC 1GH5 124 Operating Instructions 02 2016 ...
Страница 128: ...Index SIMOTICS DC 1GH5 128 Operating Instructions 02 2016 ...
Страница 129: ......
Страница 130: ...Siemens AG Process Industries and Drives Postfach 48 48 90026 NÜRNBERG GERMANY www siemens com drives ...