8.7.3
Mechanical faults
Table 8-2
Mechanical faults
↓ Grinding noise
↓ Radial vibrations
↓ Axial vibrations
Possible causes of faults
Remedial measures
X
Rotating parts grind
Establish the cause and realign the parts.
X
Rotor or coupling not balanced.
Disconnect the rotor or coupling and rebalance.
If the machine has two shaft ends, and a transmission element is only
fitted to one end, secure the fitted key at the other end to prevent it
from being thrown out. If the rotor has balance type "H" (standard
type), the fitted key must be cut back to roughly half of its length.
X
Rotor out of round, shaft bent
Consult the manufacturing plant.
X
X
Poor alignment
Align the machine set; check the coupling.
(1)
X
Coupled machine not balanced
Rebalance the coupled machine.
X
Shocks from coupled machine
Investigate the coupled machine.
X
X
Uneven running of gear unit
Fix the gearing.
X
X
Resonance of the overall system compris‐
ing motor and foundation
Stabilize the foundation following consultation.
X
X
Changes in foundation
Establish the cause of the changes and eliminate them if necessary;
realign the machine.
(1)
Take any changes into account when warming up the machine.
8.7.4
Rolling bearing faults
Damage to rolling bearings can be difficult to detect in some cases. If in doubt, replace the rolling
bearing. Use other bearing designs only after consulting the manufacturer.
Table 8-3
Rolling bearing faults
↓ Bearing overheats
↓ Bearing "whistles"
↓ Bearing "knocks"
Possible causes of faults
Remedial measures
X
High coupling pressure
Align the machine more accurately.
X
Belt tension too high
Reduce the drive belt tension.
X
Bearing contaminated
Clean or replace the bearing. Check the seals.
X
High ambient temperature
Use a suitable high-temperature grease.
X
X
Insufficient lubrication
Grease the bearings as instructed.
X
X
Bearing canted
Contact the service center.
X
X
Insufficient bearing play
Contact the service center.
X Excessive bearing play
Contact the service center.
X
X
Bearing corroded
Replace the bearing. Check the seals.
Operation
8.7 faults
1FU9
Operating Instructions, 07/2020, A5E46712792A
87
Содержание SIMOTICCS A 1FU9
Страница 1: ...Operating Instructions 1FU9 SIMOTICS A 07 2020 Edition Synchronous motors www siemens com ...
Страница 2: ......
Страница 42: ...Preparing for use 4 11 Converter operation 1FU9 40 Operating Instructions 07 2020 A5E46712792A ...
Страница 58: ...Assembly 5 6 Installing the machine 1FU9 56 Operating Instructions 07 2020 A5E46712792A ...
Страница 80: ...Commissioning 7 3 Switching on 1FU9 78 Operating Instructions 07 2020 A5E46712792A ...
Страница 110: ...Spare parts 1FU9 108 Operating Instructions 07 2020 A5E46712792A ...
Страница 120: ...Technical data B 1 Tightening torques 1FU9 118 Operating Instructions 07 2020 A5E46712792A ...
Страница 124: ...Index 1FU9 122 Operating Instructions 07 2020 A5E46712792A ...
Страница 125: ......
Страница 126: ...Germany www siemens com drives Siemens AG Digital Industries Motion Control Postfach 31 80 91050 ERLANGEN ...