6.8.3
Connecting aluminum conductors
If you are using aluminum conductors, then comply with the following:
• Use only cable lugs that are suitable for connecting aluminum conductors.
• Immediately before inserting the aluminum conductor, remove the oxide layer from the
contact areas on the conductor and/or the mating piece. Do this using a brush or file.
• Then grease the contact areas immediately using neutral Vaseline. This prevents a new oxide
layer from forming.
NOTICE
Aluminum flow due to contact pressure
Aluminum flows following installation due to the contact pressure. The connection using
clamping nuts can loosen as a result. The contact resistance increases, obstructing the
current from being conducted. This can result in fire and material damage to the machine
– or even in total failure, as well as material damage to the plant or system due to machine
failure.
• Retighten the clamping nuts after approximately 24 hours and then again after
approximately four weeks. Make sure that the terminals are de-energized before you
tighten the nuts.
6.9
Connecting converters
6.9.1
Connecting converters
NOTICE
Material damage caused by an excessively high supply voltage
Material damage can occur if the supply voltage is too high for the insulation system.
• Observe the values in the following tables.
SIMOTICS machines can be operated with SINAMICS G converters and SINAMICS S converters
(uncontrolled and controlled infeed) when maintaining the permissible peak voltages.
The insulation system of SIMOTICS machines corresponds to the specifications laid down in IEC
60034-18-41 according to voltage stress category C (IVIC C = high stress).
Table 6-6
Maximum voltage peaks at the motor terminals
Rated motor voltage
V
Maximum peak voltage at the motor terminals
Û
phase-to-phase
V
pk
Û
phase-to-ground
V
pk
DC link U
DC
V
≤ 500 V
1500
1100
750
Electrical connection
6.9 Connecting converters
1FU9
Operating Instructions, 07/2020, A5E46712792A
69
Содержание SIMOTICCS A 1FU9
Страница 1: ...Operating Instructions 1FU9 SIMOTICS A 07 2020 Edition Synchronous motors www siemens com ...
Страница 2: ......
Страница 42: ...Preparing for use 4 11 Converter operation 1FU9 40 Operating Instructions 07 2020 A5E46712792A ...
Страница 58: ...Assembly 5 6 Installing the machine 1FU9 56 Operating Instructions 07 2020 A5E46712792A ...
Страница 80: ...Commissioning 7 3 Switching on 1FU9 78 Operating Instructions 07 2020 A5E46712792A ...
Страница 110: ...Spare parts 1FU9 108 Operating Instructions 07 2020 A5E46712792A ...
Страница 120: ...Technical data B 1 Tightening torques 1FU9 118 Operating Instructions 07 2020 A5E46712792A ...
Страница 124: ...Index 1FU9 122 Operating Instructions 07 2020 A5E46712792A ...
Страница 125: ......
Страница 126: ...Germany www siemens com drives Siemens AG Digital Industries Motion Control Postfach 31 80 91050 ERLANGEN ...