![Siemens SIMATIC VS130 Series Скачать руководство пользователя страница 45](http://html.mh-extra.com/html/siemens/simatic-vs130-series/simatic-vs130-series_manual_374431045.webp)
Vision Sensor SIMATIC VS 130
A5E00199459-01
6-1
6
Controlling with a PLC
As an alternative to operator control from the control panel, you can also control
the SIMATIC VS 130 with a PLC. This makes it possible to train and work almost
automatically.
6.1
Control via the I/O Interface "DI/DO"
6.1.1 Control
Signals
You will find the pinning of the I/O interface "DI/DO" in Appendix A.5.
Input Signals
Name
Function
DISA
Disable: Disable manual control panel input, model selection and train via
digital I/O
SEL0
Select 0: Code selection: bit 0
SEL1
Select 1: Code selection bit 1 (if TRN=0) / train code (if TRN=1)
SEL2
Select 2: Code selection bit 2
SEL3
Select 3: Code selection bit 3
TRN
Train: Train new code
TRG
Trigger: An evaluation is started on the positive-going edge
RES