![Siemens SIMATIC TS Adapter IE Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/siemens/simatic-ts-adapter-ie/simatic-ts-adapter-ie_manual_374684027.webp)
Connecting
5.3 Power Supply
TS Adapter IE
Manual, 11/2010, A5E00977705-03
27
5.3
Power Supply
Power supply
The 24 V DC power is supplied to the TS Adapter IE via the power socket.
DANGER
Only safely isolated 24 V DC low voltage may be used for the power supply. Safe isolation
can be achieved according to one of the following standards:
VDE 0100-410 / HD 384-4-41 S2 / IEC 60364-4-41
(as functional extra-low voltage - FELV - with safe isolation)
VDE 0805 / EN 60950 / IEC 60950
(as safety extra-low voltage - SELV or VDE 0106 part 101.)
The wire cross-sections must meet the minimum requirements of the relevant installation
standard.
The following diagram shows the power socket on the front panel of the TS Adapter IE. The
TS Adapter IE ISDN is shown representing both variants of the TS Adapter IE.
①
0 V (GND)
②
24 V DC power socket
③
+24 V DC
Figure 5-6
Power socket
Содержание SIMATIC TS Adapter IE
Страница 6: ...Table of contents TS Adapter IE 6 Manual 11 2010 A5E00977705 03 ...
Страница 20: ...Mounting 4 4 Cubicle Mounting TS Adapter IE 20 Manual 11 2010 A5E00977705 03 ...
Страница 36: ...Connecting 5 6 Interfaces to the phone network TS Adapter IE 36 Manual 11 2010 A5E00977705 03 ...
Страница 38: ...Commissioning 6 1 Overview TS Adapter IE 38 Manual 11 2010 A5E00977705 03 ...
Страница 78: ...Error diagnostics 8 8 Error diagnostics Ethernet TS Adapter IE 78 Manual 11 2010 A5E00977705 03 ...
Страница 98: ...Specifications 9 10 Technical Support TS Adapter IE 98 Manual 11 2010 A5E00977705 03 ...
Страница 102: ...Index TS Adapter IE 102 Manual 11 2010 A5E00977705 03 ...