S7-400 cycle and response times
19.5 Response time
S7-400H
System Manual, 03/2012, A5E00267695-11
369
19.5
Response time
Definition of response time
The response time is the time from detecting an input signal to changing the output signal
associated with it.
Fluctuation range
The actual response time lies between the shortest and the longest response time. You must
always assume the longest response time when configuring your system.
The section below deals with the shortest and longest response times, in order to provide an
overview of the fluctuation in the length of response times.
Factors
The response time depends on the cycle time and the following factors:
●
Delay of the inputs and outputs
●
Additional DP cycle times on the PROFIBUS DP network
●
Execution in the user program
Delay of the I/Os
Make allowances for the following module-specific delay times:
●
For digital inputs: the input delay time
●
For digital inputs with interrupt function: the input delay time + internal preparation time
●
For digital outputs: negligible delay times
●
For relay outputs: typical delay times of 10 ms to 20 ms.
The delay of relay outputs also depends on
the temperature and voltage.
●
For analog inputs: cycle time for analog input
●
For analog outputs: response time at analog outputs
For information on delay times, refer to the technical specifications of the signal modules.
Содержание SIMATIC S7-400H
Страница 24: ...Preface 1 1 Preface S7 400H 24 System Manual 03 2012 A5E00267695 11 ...
Страница 46: ...Getting Started 4 5 Special layout features of SIMATIC Manager S7 400H 46 System Manual 03 2012 A5E00267695 11 ...
Страница 120: ...Memory concept 10 1 Overview of the memory concept of S7 400H CPUs S7 400H 120 System Manual 03 2012 A5E00267695 11 ...
Страница 258: ...Communication 14 8 General issues regarding communication S7 400H 258 System Manual 03 2012 A5E00267695 11 ...
Страница 354: ...Synchronization modules 18 3 Selecting fiber optic cables S7 400H 354 System Manual 03 2012 A5E00267695 11 ...
Страница 434: ...Technical data 20 6 Runtimes of the FCs and FBs for redundant I Os S7 400H 434 System Manual 03 2012 A5E00267695 11 ...
Страница 460: ...Function modules and communication processors supported by the S7 400H S7 400H 460 System Manual 03 2012 A5E00267695 11 ...