Communication via Function Blocks
6.4 Using the Function Blocks with the RK 512 Computer Connection
CP 341 Point-to-Point Communication, Installation and Parameter Assignment
154
Manual, 09/2008, A5E02191071-01
Time sequence chart of FB P_RCV_RK
The figure below illustrates the behavior of the NDR, LEN, and ERROR parameters
depending on the input circuit of EN_R and R.
(1B5
5
1'5
(5525
(QDEOHUHFHLYH
&RPSOHWLRQZLWKRXWHUURUV
5HFHLYLQJ
7HUPLQDWLRQZLWKHUURUV
1RWUHFHLYLQJ
5(6(7
&RPSOHWLRQZLWKRXWHUURUV
5HFHLYLQJ
7HUPLQDWLRQZLWKHUURUV
5HFHLYLQJLVVZLWFKHGRII
/(1
OHQJWK
Figure 6-5
Time sequence chart of FB 7 P_RCV_RK for "Provide data" request
Note
The EN_R input remain static at "1". The EN_R parameter must be supplied with result of
logic operation "1" during the entire receive request.
长沙工控帮教育科技有限公司
www.gkbpx.com