Program instructions
7.5 Convert
S7-200 SMART
System Manual, V2.3, 07/2017, A5E03822230-AF
245
Example: Real to ASCII
LAD
STL
Convert the real value at VD2 to 10
ASCII characters starting at VB10,
using a format of 16#A3 (a period for
the decimal point, followed by 3 dig-
its).
Network 1
LD I2.3
RTA VD2, VB10, 16#A3
See also
Assigning a constant value for instructions (Page 83)
7.5.3
Number value to ASCII string conversion
Format of the STRING data type
A string variable is a sequence of characters, with each character stored as a byte. The first
byte of the STRING data type defines the length of the string, which is the number of
character bytes.
The diagram below shows the STRING data type stored as a variable in memory. The string
can have a length of 0 to 254 characters. The maximum storage requirement for a variable
string is 255 bytes (the length byte plus 254 characters).
If a constant string parameter is entered directly in the program editor (126 characters
maximum) or a variable string is initialized in the data block editor (254 characters
maximum), the string assignment must begin and end with double quote characters.
Содержание SIMATIC S7-200
Страница 30: ...Product overview 1 7 Programming software S7 200 SMART 30 System Manual V2 3 07 2017 A5E03822230 AF ...
Страница 267: ...Program instructions 7 6 Counters S7 200 SMART System Manual V2 3 07 2017 A5E03822230 AF 267 HSC modes 3 and 4 ...
Страница 394: ...Program instructions 7 18 Subroutine S7 200 SMART 394 System Manual V2 3 07 2017 A5E03822230 AF ...
Страница 425: ...Communication 8 5 PROFIBUS S7 200 SMART System Manual V2 3 07 2017 A5E03822230 AF 425 ...
Страница 786: ...Technical specifications A 11 S7 200 SMART cables S7 200 SMART 786 System Manual V2 3 07 2017 A5E03822230 AF ...
Страница 798: ...Error codes C 4 PLC fatal error codes S7 200 SMART 798 System Manual V2 3 07 2017 A5E03822230 AF ...
Страница 848: ...Ordering information F 6 Human Machine Interface devices S7 200 SMART 848 System Manual V2 3 07 2017 A5E03822230 AF ...