Configuration
4.19 Messages
CP 1243-8 IRC
166
Operating Instructions, 02/2018, C79000-G8976-C385-03
●
Include value
If you enable the option, the CP sends a value for the placeholder $$ from the memory
area of the CPU in the message. To do this enter "$$" as a placeholder for the value to
be sent in the message text.
Select a PLC tag whose value will be integrated in the message. The value is entered in
the message text instead of the placeholder $$.
$$ can be a placeholder for data point types with a simple data type up to a size of 32
bits.
Note that with the value the number of characters increases. For the maximum number of
characters, refer to the section Performance data and configuration limits (Page 22).
●
PLC tag for value
PLC tag in which the value to be sent is written.
4.19.2
Character set for messages
Character set for message texts
The CP supports the following ASCII character set (hexadecimal value and character name)
for the texts:
●
0x0A
LF (line feed)
●
0x0D
CR (carriage return)
●
0x20
Space
●
0x21 ... 0x5A
! " # $ % & ' ( ) * + , - . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ? @ A B C D E F G H I J K L M N O P
Q R S T U V W X Y Z
●
0x5F
£
●
0x61 ... 0x7A
a b c d e f g h i j k l m n o p q r s t u v w x y z