![Siemens SIMATIC RF640A Скачать руководство пользователя страница 477](http://html.mh-extra.com/html/siemens/simatic-rf640a/simatic-rf640a_system-manual_374419477.webp)
Accessories
10.2 Power splitter for RF600 systems
SIMATIC RF600
System Manual, 11/2018, J31069-D0171-U001-A21-7618
477
10.2.3
Example of a configuration
The following example of a configuration shows a setup with one RF680R reader, one power
splitter and two RF640A antennas.
Figure 10-2 Example of a configuration with an RF600 system with a power splitter
The link between the reader and the power splitter (3.2 dB attenuation) is via a cable 1 m in
length (0.5 dB cable attenuation). Cables with a length of 5 m (1.25 dB cable attenuation) are
used between the power splitter and the antennas.
To calculate the total attenuation made up of the cable attenuation and the attenuation of the
power splitter, the various attenuation values need to be added. For the configuration shown
above, the total attenuation is as follows:
0.5 dB + 3.2 dB + 1.25 dB = 4.95 dB
The total attenuation of 4.95 dB must be stored in the configuration of the reader as user-
defined cable attenuation. When using several different antennas, the antenna gain of the
antenna with the highest gain must be specified. This ensures that the maximum permitted
transmit power is not exceeded.
Note that when using different antenna cable lengths, the radiated power of the antenna with
the longer cable is lower.
Содержание SIMATIC RF640A
Страница 12: ...Table of contents SIMATIC RF600 12 System Manual 11 2018 J31069 D0171 U001 A21 7618 ...
Страница 332: ...Antennas 6 8 SIMATIC RF680A SIMATIC RF600 332 System Manual 11 2018 J31069 D0171 U001 A21 7618 ...
Страница 486: ...Accessories 10 3 Reader and antenna holders SIMATIC RF600 486 System Manual 11 2018 J31069 D0171 U001 A21 7618 ...