7.1.5.4
Minimum distances between antennas and transponders
The antennas listed here are all far field antennas. For this reason, a minimum distance
between antennas and transponders must be maintained to ensure reliable transponder data
access:
Table 7- 7
Minimum distances to be maintained between antennas and transponders
RF600 antenna
Minimum distances to be maintained
RF615A
50 mm
RF620A
50 mm
RF640A
200 mm
RF642A
200 mm
RF650A
200 mm
RF660A
200 mm
RF680A
200 mm
RF685R, internal antenna
200 mm
7.1.6
Influence of conducting walls on the range
NOTICE
Influence of conducting walls on the range
If there are metallic (reflecting) surfaces in the immediate vicinity of the transponder, this
can have a negative effect on the write/read range. Test the environmental conditions
before using the transponder.