![Siemens SIMATIC RF640A Скачать руководство пользователя страница 336](http://html.mh-extra.com/html/siemens/simatic-rf640a/simatic-rf640a_system-manual_374419336.webp)
Transponder
7.1 Overview
SIMATIC RF600
336
System Manual, 11/2018, J31069-D0171-U001-A21-7618
7.1.4
SIMATIC memory configuration of the RF600 transponders and labels
Special memory configuration of the RF600 transponders and smartlabels
Address spaces of the transponder versions
With the RF600 readers, the user data, TID, EPC and passwords are read out via the
relevant memory banks. To read out the required data, the relevant memory bank must be
selected.
The table above shows the area and length of the user data ("USER" column). You can read
out the EPC-ID using an inventory command. As an alternative, you can also read out the
EPC-ID using a Read command to memory bank 1, start address 0x04.
Figure 7-2
Memory configuration
Note
Information on the detailed memory configuration
The memory configuration of the various transponders and smartlabels varies and depends
on the chip type used. You will find detailed information of the memory configuration in the
data sheets of the chip manufacturer.
Note
Preset EPC ID
The EPC ID of the transponders RF620T to RF680T are preset with a 12 byte long identifier.
This identifier is based on a numbering scheme. You will find more information on this in the
section "Electronic Product Code (EPC) (Page 334)".
Содержание SIMATIC RF640A
Страница 12: ...Table of contents SIMATIC RF600 12 System Manual 11 2018 J31069 D0171 U001 A21 7618 ...
Страница 332: ...Antennas 6 8 SIMATIC RF680A SIMATIC RF600 332 System Manual 11 2018 J31069 D0171 U001 A21 7618 ...
Страница 486: ...Accessories 10 3 Reader and antenna holders SIMATIC RF600 486 System Manual 11 2018 J31069 D0171 U001 A21 7618 ...