RFID Reader Interface Reference
3.4 IRfReaderApi
Mobile Readers
54
Function Manual, 12/2010, J31069-D0198-U001-A2-7618
3.4.15
GetTagMemory
GetTagMemory(tagID : string, memoryBank : uint,
startAddress : uint, dataLength : uint,
password :string) : byte[]
Parameters
● tagID
The ID of a tag whose data are to be read, given as a hexadecimal encoded string. (i. e.
each byte is represented by a two-letter hexadecimal number).
● memoryBank
The memory bank (0 - 3) from which to read data.
Valid Values for the air protocol 'ISO18000-6B,'
0 – USER MEM
Valid values for the air protocol ‘EPCC1G2’ are:
0 – Reserved
1 – EPC,
2 – TID and
3 – USER MEM.
Valid values for the air protocol ‘RF300’”are:
0 – Memory
Valid values for the air protocol ‘ISO15693’ are:
0 – Memory
● startAddress
The base address within the memory bank from which to read data.
Base addresses are specified in bytes.
● dataLength
The length in bytes of the data to be read.
● Password
An access password if needed. The ISO18000-6B protocol e.g. does not support a
password. So just pass an empty string.
A password is a hexadecimal encoded string of up to eight characters.
Return value(s)
An array of bytes containing the specified tag memory's contents.
In case of errors null is returned.
Exceptions
RfReaderApiException
Error while communicating with the reader service.
Check the Error member for more information.