RFID Reader Interface Reference
3.4 IRfReaderApi
Mobile Readers
Function Manual, 12/2010, J31069-D0198-U001-A2-7618
47
3.4.6
SetAirProtocol
SetAirProtocol( protocolName : string, initialQ : int) : void
Parameters
● protocolName
A string specifying the air protocol to be set.
● initialQ
An integer value that denotes the initialQ value used for collision detection with EPC
Class1 Gen 2 tags.
This parameter is ignored if an air protocol other than 'EPCC1G2' is specified.
Return value(s)
None
Exceptions
RfReaderApiException
Error while communicating with the reader service. Check the Error
member for more information.
Note
This method is an alternate choice instead of the AirProtocol property described earlier. In
contrast to the property, it allows an additional parameter (initialQ) to be specified for the
EPC Class1 Gen2 protocol.
Version information
Supported in RFID Reader Interface: since V1.0
3.4.7
SetAntennaPower
SetAntennaPower (power : uint) : void
Parameters
•
power
The antenna power in mW.
Return value(s)
None
Exceptions
RfReaderApiException
Error while starting the communication with the reader. Check
the Error member for more information.