RfReaderInitData Member
Description
Address
Set the IP address for the device. This value defaults to 127.0.0.1
which is the local device.
Port
The port which is used for communication between the API and the
underlying reader service. Defaults to 4684, which is the EPC default
port.
Type
Supported Types:
- RF310M
1)
- RF610M
- - RF680M
2)
Default is RF610M. Any other type will be refused
AdditionalInitData
Additional initialization data for other readers. Currently always empty.
(This member is provided for future use)
1) since Reader interface V1.2
2) since Reader Interface V1.3
Return value(s)
None
Exceptions
ArgumentOutOfRangeException
Validation of the contents of initData failed. Check the values
provided.
RfReaderApiException
Error while starting the communication with the reader. Check
the Error member for more information.
Note
Initiates the communication to an underlying reader service application that manages the
physical RFID reader device.
Most often you only need to specify only a single parameter when instantiating
RfReaderInitData, which is the mode that specifies whether the RFID reader interface should
be used from a standalone application or within an RF-MANAGER configured system.
Version information
Supported in RFID Reader Interface: since V1.0
3.4.3
StopReader
StopReader() : void
Parameters
None