![Siemens SIMATIC RF300 Скачать руководство пользователя страница 375](http://html.mh-extra.com/html/siemens/simatic-rf300/simatic-rf300_system-manual_374416375.webp)
8.20.2
Ordering data
Table 8-55
Ordering data of MDS D426
Article number
MDS D426
6GT2600-4AH00
Table 8-56
Ordering data of MDS D426 accessories
Article number
Spacer
6GT2690-0AL00
8.20.3
Mounting on metal
Direct mounting of the transponder on metal is not permitted. A distance of ≥ 20 mm is
recommended to avoid a reduced read/write range and a reduction of the field data. This can be
accomplished, for example, by installing a spacer.
Note that if the distances (a and h) are not observed, this may result in a reduction of the field
data as well as a reduced write/read range.
Mounting on metal
6SDFHU
0HWDO
7UDQVSRQGHU
K
h ≥ 25 mm
Figure 8-53
Mounting the MDS D126 / D426 / D526 on metal with spacer
ISO transponder
8.20 MDS D426
SIMATIC RF300
System Manual, 02/2021, C79000-G8976-C345-09
375
Содержание SIMATIC RF300
Страница 14: ...Table of contents SIMATIC RF300 14 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 18: ...Introduction 1 1 Preface SIMATIC RF300 18 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 22: ...Safety information 2 1 Security information SIMATIC RF300 22 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 208: ...Readers 5 6 SIMATIC RF382R with Scanmode 1st generation SIMATIC RF300 208 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 258: ...Antennas 6 10 ANT 30 stainless steel variant SIMATIC RF300 258 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 474: ...Service Support SIMATIC RF300 474 System Manual 02 2021 C79000 G8976 C345 09 ...