6.1.3
Flush-mounted in metal
The antenna ANT 1 can be flush-mounted in metal. Allow for a possible reduction in the field
data. During installation, maintain the minimum distance a flush with the metal.
Note
Reduction of range if the metal-free space is not maintained
At a value lower than a, the field data changes significantly, resulting in a reduction in the limit
distance and operating distance. Therefore, maintain the minimum distance a flush with the
metal during installation.
0HWDO
D
D
a =
40 mm
Figure 6-1
ANT 1 flush-mounted in metal
6.1.4
Minimum clearances
Note
Extension of the data transmission time if distance values are undershot
If the distance values specified in the tables are undershot, it is possible that the inductive fields
will be affected. In this case, the data transmission time can increase unpredictably or a
command is aborted with an error.
For this reason, please observe the values in the tables.
Antennas
6.1 ANT 1
SIMATIC RF300
210
System Manual, 02/2021, C79000-G8976-C345-09
Содержание SIMATIC RF300
Страница 14: ...Table of contents SIMATIC RF300 14 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 18: ...Introduction 1 1 Preface SIMATIC RF300 18 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 22: ...Safety information 2 1 Security information SIMATIC RF300 22 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 208: ...Readers 5 6 SIMATIC RF382R with Scanmode 1st generation SIMATIC RF300 208 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 258: ...Antennas 6 10 ANT 30 stainless steel variant SIMATIC RF300 258 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 474: ...Service Support SIMATIC RF300 474 System Manual 02 2021 C79000 G8976 C345 09 ...