Protocols for the configuration of the reader
6.3 [0x83] Set Default Configuration (Reset)
RF290R
Configuration Manual, 09/2014, C79000-G8976-C377-01
45
Name
Description
LOC
specifies the memory location of the configuration block
•
b0 RAM
•
b1 EEPROM
CFG-REC 14 byte long configuration block read from address CFGn in CFG-ADR
2)
For more information, refer to the section "Configuration parameters (CFG) (Page 21)".
Note
Error code 0x16
A write configuration to the EEPROM with reserved configuration blocks causes an error
code 0x16.
6.3
[0x83] Set Default Configuration (Reset)
With the "Set Default Configuration" command, you can reset every configuration block to
the default settings of the manufacturer.
Table 6- 5
Host → reader
Byte
1
2
3
4
5
6
7, 8
Content
STX
MSB
ALENGTH
LSB
ALENGTH
COM-ADR
[0x83]
CFG-ADR
CRC16
Default
0x02
-
-
-
-
-
-
Table 6- 6
Reader → host
Byte
1
2
3
4
5
6
7, 8
Content
STX
MSB
ALENGTH
LSB
ALENGTH
COM-ADR
[0x83]
STATUS
1)
CRC16
Default
0x02
-
-
-
-
-
-
1)
You will find further information in the Appendix (Page 103).
Name
Description
CFG-
ADR
2)
Bit
7
6
5
4
3
2
1
0
Function
LOC
MODE
CFGn: Address of the configuration block
Function
Description
CFGn
Memory address of the required configuration block
MODE
specifies one or all configuration blocks:
•
b0 configuration block specified by CFGn
•
b1 all configuration blocks