Configuration parameters (CFG)
5.15 CFG17: Reserved
RF290R
40
Configuration Manual, 09/2014, C79000-G8976-C377-01
Name
Description
PER-
RESET-
TIME
The time value specifies a time that specifies the resetting of the transponder selected status using RF reset
of the reader. The time PER-RESET-TIME starts after the reader receives a response from any transponder.
When this time expires, the reader generates an RF reset. The PER-RESET-TIME only takes effect if the
reader does not use MUX. If MUX is used, the transponder status is reset when there is a switchover from one
antenna to the next.
•
Time units = 5 ms
•
Maximum time value = 5 ms x 65534[0xFFFE] = 5.46125 min.
•
The value 65535 [0xFFFF] indicates that the reader will not run an RF reset.
5.15
CFG17: Reserved
The configuration block CFG17 is reserved.