Configuration parameters (CFG)
5.11 CFG13: Scan Mode
RF290R
Configuration Manual, 09/2014, C79000-G8976-C377-01
35
Note
Please note the following:
•
A change to TR-ID only takes effect after configuration block CFG12 has been written to
the EEPROM and the CPU has been reset.
•
The address TR-ID-DB-ADR must be in the range of the selected data blocks:
DB-ADR
≤ TR
-ID-DB-
ADR ≤ DB
-ADR1 + DB-N1 - 1.
"DB-ADR" and "DB-N" are from CFG11.
•
If instead of the "serial number", the TR-ID source "Data block" is used, the reading of
data blocks in "CFG11: Read mode - read data (Page 31)" must also be activated and
configured.
5.11
CFG13: Scan Mode
Byte
0
1
2
3
4
5
6
Content
DB-USE
SEP-CHAR
SEP-USER
END-CHAR
END-USR1
END-USR2
END-USR3
Default
0x02
0x20
0x2C
0x01
0x00
0x00
0x00
Byte
7
8
9
10
11
12
13
Content
0x00
HEADER-
USR1
HEADER -
USR2
HEADER -
USR3
HEADER -
USR4
0x00
LEN-USR
Default
-
0x00
0x00
0x00
0x00
-
0x00
Name
Description
DB-USE
Defines the data format of the data and the value of the data.
Bit
7
6
5
4
3
2
1
0
Function
0
0
0
0
DB-FORMAT
Function
Description
DB-
FORMAT
•
b0000 unformatted hex data
In this case, the data is transferred as it was read by the reader.
•
b0010 ASCII-formatted hex data
In this case the raw data is converted to ASCII code by the transponder before the transfer.
For this, the data bytes are first divided into half bytes and then converted to ASCII characters
as shown in the following table.
Raw data
(hex / binary)
ASCII data
(ASCII / hex)
0x0
b0000
'0'
0x30
0x1
b0001
'1'
0x31
0x2
b0010
'2'
0x32