6.2.5
Minimum spacing
Note
Extension of the data transmission time if distance values are undershot
If the distance values specified in the tables are undershot, it is possible that the inductive
fields will be affected. In this case, the data transmission time can increase unpredictably or
a command is aborted with an error.
For this reason, please observe the values in the tables.
Minimum distances from transponder to transponder (without multitag mode)
Table 6- 8
Minimum distances transponder edge to transponder edge
MDS D124 / MDS D160 / MDS D324 /
MDS D423 / MDS D424 / MDS D428 /
MDS D460 / MDS D524 / MDS D528
MDS D422 / MDS D425 / MDS D522
RF250R with ANT 3
> 80 mm
> 60 mm
Minimum distances from antenna to antenna
D
≥ 150
mm
Figure 6-7
Minimum distance for ANT 3