Service and maintenance
10.2 Error messages
SIMATIC RF166C
142
Operating Instructions, 12/2019, C79000-G8976-C578-01
10.2.2
Reading out error messages using the WBM
Reading out error messages using the WBM
All the diagnostics messages of the communication module are entered in the "Log" if a
check mark was set for "ERRORS" in the WBM configuration in "Settings - General". You will
find further information on the "Log" in the section "The "Diagnostics - Log" menu item
(Page 82)".
10.2.3
OPC UA error messages
The following table lists the OPC UA-specific error codes.
Table 10- 8 OPC UA error messages of the communications module
AutoId
status
OPC UA
status
AutoId
text
Error description
1
good
MISC_ERROR_
TOTAL
General error
1
good
MISC_ERROR_
TOTAL
•
Firmware error
Possible cause: The firmware update was not run complete-
ly.
•
Internal communications error of the communications mod-
ule/reader
–
Connector contact problem on the communications
module / reader
–
Hardware of the communications module/reader has a
defect;
→
Send in communications module/reader for re-
pair
–
Start "INIT" after correcting the error
•
Internal monitoring error of the communications mod-
ule/reader
–
Program execution error on the communications module
/ reader
–
Turn the power supply of the communications mod-
ule/reader off and on again
–
Start "INIT" after correcting the error
1
good
MISC_ERROR_
TOTAL
The inventory command failed.
1
good
MISC_ERROR_
TOTAL
Enabling write protection on the transponder has failed.
1
good
MISC_ERROR_
TOTAL
The "Kill" command failed.
3
good
PERMISSON_
ERROR
The transponder is read/write-protected.
Содержание SIMATIC RF166C
Страница 6: ...Table of contents SIMATIC RF166C 6 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 14: ...Security recommendations SIMATIC RF166C 14 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 20: ...Description 3 3 Design SIMATIC RF166C 20 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 98: ...Programming via SIMATIC controller SIMATIC RF166C 98 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 156: ...Service and maintenance 10 5 Module replacement SIMATIC RF166C 156 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 160: ...Dimensional drawings SIMATIC RF166C 160 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 176: ...Service Support SIMATIC RF166C 176 Operating Instructions 12 2019 C79000 G8976 C578 01 ...