3
3-2
PG 760 Programming Device
C79000-G7076-C761-01
3.1
Connecting the PG 760 to the Power Supply
The PG 760 can be operated at 120 V or 230 V. Voltage selection is carried
out via the mains voltage selector.
!
Caution
Risk of damage to the unit!
Operating the PG 760 with the incorrect mains voltage can damage the unit.
When switched on, the same voltage is present on the appliance socket
(outlet) as on the appliance plug (mains inlet). To operate the monitor, please
observe the manufacturer’s specifications. Only a monitor with the following
rated currents may be connected to the appliance socket:
S
115 V
1 A max.
S
230 V
0.5 A max.
If the set voltage does not correspond to your local voltage, you must select
the correct voltage by moving the mains voltage selector either to 115 V or
230 V. Proceed as follows:
Proceed as follows to switch over the voltage:
1. For 120 V, using a normal screwdriver push the mains voltage selector
right. 115 V appears above the switch.
2. For 230 V, using a normal screwdriver push the mains voltage selector
left. 230 V appears below the switch.
Mains voltage Selector
Appliance socket
(outlet)
Appliance plug
(inlet)
Mains voltage
selector
230 Volt
115 Volt
Figure 3-1 Mains Voltage Selector
Connecting to the
Power Supply
Selecting Mains
Voltage
Installing and Operating the PG 760