Servicing and Expanding the Computing Unit
Release 11/02
4-13
SIMATIC Panel PC 870 Computing Unit, Equipment Manual
2. Remove the surplus slide element:
– Score the slide element at the top edge of the support with a knife and snap
it off.
– Nip off the surplus with a sharp side cutter.
4.3.2
Installing ISA/PCI cards
Notes on the modules
The computer unit is designed for the use of cards as per the AT/PCI specification.
The dimensions of the cards must not exceed the stated dimensions. If the height
is exceeded, contact problems, malfunctions and difficulties with installation cannot
be ruled out. The illustrations show full length AT/PCI cards. Depending on the slot,
there might be constraints concerning the overall length.
340,7
121.92
A31
A1
All dimensions in mm
C18
C1
(13.41)
(4.8)
All dimensions ( ) in inches
Figure 4-11
AT card
312
106,68
8,19
(12,28)
(4,2)
(0,32)
Figure 4-12
Long PCI card (5 V)