Functions
9.4 Fan monitoring
SIMATIC Rack PC 847B
Operating Instructions, 06/2008, A5E02203168-01
59
9.4
Fan monitoring
Operation of the front / processor / power unit fans is monitored. The following reactions are
triggered when a fan fails:
Reaction
Option
The fan LED switches to red
None
SIMATIC monitoring software is activated
None
The fan fault is retained in memory until the cause of the fan failure has been rectified and
the error is reset by taking one of the following measures:
●
Acknowledgment of the error message by the SOM program or DiagMonitor software.
●
Restart of the device.
9.5
RAID monitoring
In conjunction with the SIMATIC monitoring software and in addition to the RAID software,
the status of the RAID system is shown on the HDD1 alarm and HDD2 alarm front LEDs. For
detailed information on the RAID system and on the operation of the RAID software, refer to
the RAID section.
Reaction
Description
Option
Off
RAID system is ready for operation. SIMATIC
software is not active.
One is red
Drive 1 or Drive 2 has failed.
Both are red
RAID system is not ready for operation.
Affected drive must be determined with the
help of the RAID software.
HDD1 alarm
HDD2 alarm
Both flash
RAID system is currently being synchronized.
None