4.1
Securing with clamps
Range of validity
Skip this step if you have selected "screw mounting."
Requirements
•
The installation cut-out has been completed.
•
Clamps are readily available in the accessories. Clamp and grub screws are included in
the contents of delivery.
Figure 4-1
Clamp assembly
Procedure
1. Follow the installation guidelines.
2. Working from the front, insert the device into the installation cut-out.
3. Secure the control unit in the installation cut-out from behind with the clamps, as shown in
the installation cut-out in the dimension diagrams. Tighten the grub screw to a torque of
0.4-0.5 Nm.