Technical specifications
Effective power loss
DC rated voltage
With connected
LPE
62.4 W
Without LPE
43.2 W
Cable cross-section
Minimum
0.75 mm
2
(AWG 18)
Maximum
2.5 mm
2
(AWG 12)
Permitted ambient conditions
Ambient temperature
With operation up to 2000 m above
sea level
During operation in horizontal installation po‐
sition (position 1):
-40 °C to +60 °C
During operation in a different installation po‐
sition (positions 2, 3 and 4):
-40 °C ... +50 °C
During operation between 2000 m
and 3000 m above sea level
-35 °C to +60 °C
During operation between 3000 m
and 4000 m above sea level
-30 °C to +60 °C
During storage
-40 °C to +85 °C
During transportation
-40 °C to +85 °C
Relative humidity
During operation at 25 ℃
≤ 95% without condensation
Housing, dimensions and weight
Design
compact
Housing material
Basic housing
Die cast aluminum, powder coated
Front cover
Polycarbonate (PC-GF10)
Degree of protection
IP20
Dimensions (W x H x D)
210 x 147 x 125 mm
Weight
2040 g
Installation options
• Wall mounting
• Installation on a DIN rail
• Mounting on an S7-300 standard rail
• Mounting on an S7-1500 standard rail
Mounting restriction
Observe mounting positions (Page 34)
Conformal coating of the PCBs
No
Mean time between failure (MTBF)
MTBF (EN/IEC 61709; 40 °C)
11.6 years
1)
Note the wiring rules (Page 48).
Technical specifications
9.1 Technical specifications of SCALANCE XCM332
64
SCALANCE XCM-300
Product
Manual, 04/2022, C79000-G8976-C585-01
Содержание SIMATIC NET SCALANCE XCM-300
Страница 6: ...Table of contents 6 SCALANCE XCM 300 Product Manual 04 2022 C79000 G8976 C585 01 ...
Страница 12: ...Safety notices 12 SCALANCE XCM 300 Product Manual 04 2022 C79000 G8976 C585 01 ...
Страница 58: ...Maintenance and cleaning 58 SCALANCE XCM 300 Product Manual 04 2022 C79000 G8976 C585 01 ...
Страница 80: ...Certifications and approvals 80 SCALANCE XCM 300 Product Manual 04 2022 C79000 G8976 C585 01 ...