6.3
Wiring rules
When wiring use cables with the following AWG categories or cross sections.
Wiring rules for ...
Spring-loaded terminals
connectable cable cross sec‐
tions for flexible cables ...
without wire end ferrule
0.2 - 1.5 mm
2
AWG: 24 - 14
with wire end ferrule with plastic
ferrule**
0.25 - 0.75 mm
2
AWG: 24 - 14
with TWIN wire end ferrule without
plastic ferrule**
0.25 - 1.5 mm
2
AWG: 24 - 18
Stripped length of the cable
10 mm
Wire end ferrule according to DIN 46228 without plastic ferrule**
10 mm
* AWG: American Wire Gauge
** See note "Wire end ferrules"
Note
Wire end ferrules
Use crimp shapes with smooth surfaces, such as provided by square and trapeze shaped crimp
cross sections.
Crimp shapes with wave-shaped profile are unsuitable.
Connecting up
6.3 Wiring rules
SCALANCE XB-200
38
Operating Instructions, 03/2020, C79000-G8976-C359-09
Содержание SIMATIC NET SCALANCE XB-200 Series
Страница 10: ...Safety notices SCALANCE XB 200 10 Operating Instructions 03 2020 C79000 G8976 C359 09 ...
Страница 16: ...Recommendations on network security SCALANCE XB 200 16 Operating Instructions 03 2020 C79000 G8976 C359 09 ...
Страница 32: ...Installation 5 2 Mounting on DIN rails SCALANCE XB 200 32 Operating Instructions 03 2020 C79000 G8976 C359 09 ...