Installation, connecting up, sources of problems
4.1 Assembly
SCALANCE X-100
44
Operating Instructions, 04, A2B00060666D
Uninstalling
To remove Industrial Ethernet switches of the SCALANCE X-100 product line from the
SIMATIC S7-300 standard rail:
1.
First disconnect all connected cables.
2.
Loosen the device screws on the underside of the S7 standard rail and lift the device
away from the rail.
4.1.3
Wall mounting
Wall mounting
1.
For wall mounting, use suitable mounting fittings for the wall
(for example, for a concrete wall, four plugs 6 mm diameter and 30 mm long, 4 screws
3.5 mm diameter and 40 mm long).
2.
Connect the electrical cable connecting cables.
3.
Fit the connectors for the signaling contact.
4.
Insert the terminal blocks into the sockets on the device.
For more exact dimensions, please refer to the section "Dimension drawings".
Note
The wall mounting must be capable of supporting at least four times the weight of the device.
Содержание SIMATIC NET SCALANCE X-100 Series
Страница 40: ...Product properties 3 12 Displays SCALANCE X 100 40 Operating Instructions 04 A2B00060666D ...
Страница 54: ...Approvals and markings SCALANCE X 100 54 Operating Instructions 04 A2B00060666D ...
Страница 60: ...Technical specifications 6 1 Technical specifications SCALANCE X 100 60 Operating Instructions 04 A2B00060666D ...
Страница 62: ...References SCALANCE X 100 62 Operating Instructions 04 A2B00060666D ...
Страница 68: ...Dimension drawings 8 1 Dimension Drawing SCALANCE X 100 68 Operating Instructions 04 A2B00060666D ...
Страница 72: ...Glossary SCALANCE X 100 72 Operating Instructions 04 A2B00060666D ...
Страница 74: ...Index SCALANCE X 100 74 Operating Instructions 04 A2B00060666D U UL approval 6 ...