Configuring with Web Based Management
6.8 "Layer 3 (IPv4)" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
352
Configuration Manual, 08/2018, C79000-G8976-C267-13
Procedure
1.
In the "Local Interface IP address" input box, enter the local IP address of the Ethernet
interface.
2.
In the "Local Interface Subnet Mask" input box, enter the subnet mask for the local
Ethernet.
3.
Enable NAT for the Ethernet interface.
4.
Enter the PROFINET device name.
5.
Click the "Set Values" button.
6.8.1.2
NAPT
Note
This page is only available in client mode.
On this WBM page, you define the translation list for communication from the global to the
local network. Per WLAN client (NAT gateway), 60 entries are possible.
Description
The page contains the following boxes:
●
Interface
Interface to which the settings relate. Can only be selected if the device has several
interfaces.
●
Traffic Type
Specify the protocol for which the address assignment is valid. TCP and UDP frames
must have parameters set separately.