Configuring with Web Based Management
6.5 "System" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
196
Configuration Manual, 08/2018, C79000-G8976-C267-13
on every WBM page until either the changes made have taken effect or the
SCALANCE W device has been restarted.
Note
When the changes take effect, the WLAN connections to all WLAN interfaces will be
interrupted for a short time. The WLAN driver is started with the new settings.
6.5.8
Load & Save
Note
The files that can be loaded from the device depends on the role of the logged-on.
Overview of the file types
Table 6- 1
HTTP
File type
Description
Down-
load
Save
Delete
Config
This file contains the start configuration.
Among other things, this file contains the definitions
of the users, roles, groups and function rights. The
passwords are stored in the "Users" file.
X
X
--
ConfigPack Detailed configuration information. for example,
start configuration, users, certificates, favorites,
firmware of the device (if saved as well).
For more detailed information on creating and us-
ing the ConfigPack incl. firmware, refer to the sec-
tion "Maintenance (Page 421)".
X
X
--
CountryList The zip file contains the country list as a csv and as
a pdf file.
--
X
--
Debug
This file contains information for Siemens Support.
It is encrypted and can be sent by e-mail to Sie-
mens Support without any security risk.
--
X
X
EDS
Electronic Data Sheet (EDS)
Electronic data sheets for describing devices in the
EtherNet/IP mode
--
X
--
Firmware
The firmware is signed and encrypted. This en-
sures that only firmware created by Siemens can
be downloaded to the device.
X
X
--
GSDML
Information on the device properties (PROFINET)
--
X
--
HTTPS Cert HTTPS certificate
Maximum file size: 8192 bits
X
X
X
LogFile
File with entries from the event log table
--
X
--