Configuring with Web Based Management
5.9 "Security" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
286
Configuration Manual, 03/2015, C79000-G8976-C267-08
Description
The page contains the following boxes:
●
"Port" drop-down list
Select the required port from the drop-down list.
●
IP Address" input box
Enter the IP address of the devices accessible to the client.
The table has the following columns:
●
Select
Select the check box in the row to be deleted
●
Radio
Specifies the WLAN interface to which the settings relate
●
Port
Specifies the VAP interface to which the settings relate
●
IP Address
The IP address of the devices accessible to the client. If necessary, you can change the
IP address.
●
Resolver IP Address
The IP address with which the permitted IP address is resolved. The entry is necessary
when the management IP address is located in a different subnet.
If the IP address "0.0.0.0" is configured for "Resolve IP Address", the management IP
address is used for resolution.
Procedure
Creating an entry
1.
Select a port from the "Port" drop-down list.
2.
In the "IP Address" box, enter the IP address accessible for the client.
3.
Click the "Create" button. A new entry is created in the table.
Deleting an entry
1.
Enable "Select" in the row to be deleted.
2.
Click the "Delete" button. The entry is deleted.