Configuring with Web Based Management
5.5 "System" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 03/2015, C79000-G8976-C267-08
139
●
"DNS Client" check box
Enable or disable the DNS client. You can configure other settings in "System > DNS
Client".
●
"SMTP Client" check box
Enable or disable the SMTP client. You can configure other settings in "System > SMTP
Client".
●
"Syslog Client" check box
Enable or disable the Syslog client. You can configure other settings in "System > Syslog
Client".
●
"DCP Server" drop-down list
Specify whether or not the device can be accessed with DCP (Discovery and
Configuration Protocol):
–
"-" (disabled)
DCP is disabled. Device parameters can neither be read nor modified.
–
Read/Write
With DCP, device parameters can be both read and modified.
–
Read-Only
With DCP, device parameters can be read but cannot be modified.
●
"Time"drop-down list
Select the setting from the drop-down list. The following settings are possible:
–
Manual
The system time is set manually. You can configure other settings in "System > Time
> Manual Setting".
–
SIMATIC Time
The system time is set using a SIMATIC time transmitter. You can configure other
settings in "System > System Time > SIMATIC Time Client".
–
SNTP Client
The system time is set via an SNTP server. You can configure other settings in
"System > System Time > SNTP Client".
–
NTP Client
The system time is set via an NTP server. You can configure other settings in "System
> System Time > NTP Client".
●
"SNMP" drop-down list:
Select the protocol from the drop-down list. The following settings are possible:
–
"-" (SNMP disabled)
Access to device parameters via SNMP is not possible.
–
SNMPv1/v2c/v3
Access to device parameters is possible with SNMP versions 1, 2c or 3. You can
configure other settings in "System > SNMP > General".
–
SNMPv3
Access to device parameters is possible only with SNMP version 3. You can configure
other settings in "System > SNMP > General".
●
"SNMPv1/v2 Read-Only" check box
Enable or disable write access to SNMP variables with SNMPv1/v2c.