Device Management
3
This section describes how to connect to and manage the device.
3.1
Connecting to the Device
The following describes the various methods for accessing the RUGGEDCOM
RSG2488F console and Web interfaces on the device. For more detailed instructions,
refer to the
RUGGEDCOM ROS-F Configuration Manual
for the RUGGEDCOM
RSG2488F.
Serial Console and Management Ports
Connect a workstation directly to the serial console or management ports to access
the boot-time control and RUGGEDCOM RSG2488F interfaces. The serial console
port provides access to RUGGEDCOM RSG2488F's console interface, while the
management port provides access to RUGGEDCOM RSG2488F's console and Web
interfaces.
The serial console port implements RS-232 DCE (Data Communication Equipment) on
a DB9 connector. The following is the pin-out for the port:
5
9
6
1
Figure 3.1
Serial DB9 Console Port
Pin
Name
Description
1
DCD
Data Carrier Detect
2
RX
Receive Data
3
TX
Transmit Data
4
DTR
Data Terminal Ready
5
GND
Signal Ground
6
DSR
Data Set Ready
7
RTS
Request to Send
RUGGEDCOM RSG2488F
Installation Manual, 07/2021, C79000-G8976-1351-07
21