background image

Edition

02/2020

Installation Manual

SIMATIC NET

Rugged Ethernet Switches

RUGGEDCOM RS930L

https://www.siemens.com

Содержание SIMATIC NET RUGGEDCOM RS930L

Страница 1: ...Edition 02 2020 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM RS930L https www siemens com ...

Страница 2: ...ed Ethernet Switches RUGGEDCOM RS930L Installation Manual Preface Introduction 1 Installing the Device 2 Device Management 3 Communication Ports 4 Technical Specifications 5 Certification 6 02 2020 C79000 G8976 1034 06 ...

Страница 3: ... personnel are those who based on their training and experience are capable of identify ing risks and avoiding potential hazards when working with these products systems Proper Use of Siemens Products Note the following WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation If products and components from other manufactur...

Страница 4: ...Locations 6 2 3 Mounting the Device 7 2 3 1 Mounting the Device on a DIN Rail 7 2 3 2 Mounting the Device to a Panel 9 2 4 Connecting the Failsafe Alarm Relay 10 2 5 Connecting Power 11 2 5 1 Connecting High AC DC Power 12 2 5 2 Connecting Low DC Power 14 3 Device Management 17 3 1 Connecting to the Device 17 3 2 Configuring the Device 18 4 Communication Ports 19 4 1 Copper Ethernet Ports 19 4 2 E...

Страница 5: ...ating Environment 27 5 6 Mechanical Specifications 27 5 7 Dimension Drawings 27 6 Certification 31 6 1 Approvals 31 6 1 1 CSA 31 6 1 2 FCC 32 6 1 3 FDA CDRH 32 6 1 4 ISED 32 6 1 5 TÜV SÜD 32 6 1 6 ACMA 33 6 1 7 RoHS 33 6 1 8 Other Approvals 33 6 2 EMC and Environmental Type Tests 34 iv RUGGEDCOM RS930L Installation Manual 02 2020 C79000 G8976 1034 06 ...

Страница 6: ...ilable online at https support industry siemens com To request or inquire about a user document con tact Siemens Customer Support Disclaimer of Liability Siemens has verified the contents of this document against the hardware and or soft ware described However deviations between the product and the documentation may exist Siemens shall not be liable for any errors or omissions contained herein or ...

Страница 7: ...on about training services and course availability visit https www siemens com or contact a Siemens Sales representative Customer Support Customer support is available 24 hours 7 days a week for all Siemens customers For technical support or general information contact Siemens Customer Support through any of the following methods Online Visit http www siemens com automation support request to subm...

Страница 8: ...try Sector 300 Applewood Crescent Concord Ontario Canada L4K 5C7 Telephone Toll free 1 888 264 0006 Tel 1 905 856 5288 Fax 1 905 856 1995 E Mail ruggedcom info i ia siemens com Web https www siemens com RUGGEDCOM RS930L Installation Manual 02 2020 C79000 G8976 1034 06 vii ...

Страница 9: ...Preface Contacting Siemens viii RUGGEDCOM RS930L Installation Manual 02 2020 C79000 G8976 1034 06 ...

Страница 10: ...urges typical of environments found on plant floors and curb side traffic control cabinets An operating temperature range of 40 to 85 C 40 to 185 F coupled with hazardous location certification Class I Division 2 op tional conformal coating and a galvanized steel enclosure allows the RUGGEDCOM RS930L to be placed in almost any location The RUGGEDCOM RS930L can be mounted on a DIN rail or panel for...

Страница 11: ...nting options provide secure mechanical reliability Optional Conformal coated printed circuit boards Universal Power Supply Options Fully integrated power supply Universal high voltage range 125 250 VDC or 100 240 VAC Hazardous Environments 88 300 VDC or 85 264 VAC Non Hazardous Environments Terminal blocks for reliable maintenance free connections CSA UL 60950 1 safety approved to 85 C 185 F 1 2 ...

Страница 12: ...ole port refer to Connect ing to the Device Page 17 Communication Ports Communication ports in general receive and transmit data as well as provide access to the RUGGEDCOM RUGGEDCOM RS930L Web in terface For more information about the various ports available re fer to Communication Ports Page 19 Failsafe Alarm Relay Latches to default state when a power disruption or other alarm condition occurs F...

Страница 13: ...has been fully decommissioned For more information refer to the associated Configuration Manual Recycling and Disposal For environmentally friendly recycling and disposal of this device and related acces sories contact a facility certified to dispose of waste electrical and electronic equip ment Recycling and disposal must be done in accordance with local regulations 1 5 Cabling Recommendations Al...

Страница 14: ...T This product contains no user serviceable parts Attempted service by unauthorized personnel shall render all warranties null and void Changes or modifications not expressly approved by Siemens AG could invalidate specifications test results and agency approvals and void the user s authority to operate the equipment IMPORTANT This product should be installed in a restricted access location where ...

Страница 15: ... that is considered to be not accessible in normal operation without the use of a tool providing a degree of protection of not less than IP54 The enclosure should have a minimum service temperature range of 40 to 100 C 40 to 212 F The equipment should be used in an area of not more than pollution degree 2 The console port should only be used in the safe area The equipment should be appropriately c...

Страница 16: ...ional airflow Forced airflow is not required However any increase in airflow will result in a reduc tion of ambient temperature and improve the long term reliability of all equipment mounted in the rack space Note For detailed dimensions of the device with either DIN rail or panel hardware installed refer to Dimension Drawings Page 27 2 3 1 Mounting the Device on a DIN Rail The RUGGEDCOM RS930L ca...

Страница 17: ...liding release with a slot at the bottom for a flathead screwdriver 1 2 3 2 1 1 1 DIN Rail 2 DIN Rail Adapter Figure 2 1 Mounting the Device to a DIN Rail 2 Insert a flathead screwdriver into the slot of the sliding release and move it down 3 Push the device against the bottom of the DIN rail then let go of the sliding re lease to latch the device 8 RUGGEDCOM RS930L Installation Manual 02 2020 C79...

Страница 18: ...il 2 Swing the bottom of the device away from the DIN rail 3 Lift the device off the DIN rail 2 3 2 Mounting the Device to a Panel For panel installations the RUGGEDCOM RS930L can be equipped with panel adapters on the top and bottom of the chassis The adapters allow the device to be attached to a panel using screws To mount the device to a panel do the following 1 Prepare mounting holes in the pa...

Страница 19: ...d and there are no ac tive alarms If the device is not powered or if an active alarm is configured the relay opens the NO contact and closes the NC Normally Closed contact Note Control of the failsafe relay output is configurable through RUGGEDCOM RS930L One common application for this relay is to signal an alarm if a power failure occurs For more information refer to the RUGGEDCOM RS930L User Gui...

Страница 20: ...led For 125 250 VDC rated equipment an appropriately rated DC circuit breaker must be installed Use minimum 16 gage copper wiring when connecting terminal blocks Equipment must be installed according to applicable local wiring codes and standards All line to ground transient energy is shunted to the Surge Ground terminal In cases where users require the inputs to be isolated from ground remove the...

Страница 21: ...l hazard risk of damage to equipment Before testing the dielectric strength HIPOT in the field remove the braided ground cable connected to the surge ground terminal and chassis ground This cable connects transient suppression circuitry to chassis ground and must be removed in order to avoid damage to transient suppression circuitry during testing Note Torque all terminal connections to 0 6 N m 5 ...

Страница 22: ...om the power source to the positive live L termi nal on the terminal block 4 1 2 3 1 Positive Live L Terminal 2 Negative Neutral N Terminal 3 Surge Ground Terminal 4 Braided Ground Cable Figure 2 5 Terminal Block Wiring RUGGEDCOM RS930L Installation Manual 02 2020 C79000 G8976 1034 06 13 ...

Страница 23: ...om the power source to the chassis groun terminal on the terminal block 2 5 2 Connecting Low DC Power RUGGEDCOM RS930L s equipped with 24 or 48 V power supply inputs feature reverse polarity protection and dual power supply inputs allowing the device to accept re dundant connections to a single DC power supply To connect a low DC power supply to the device do the following Note Torque all terminal...

Страница 24: ...erminal block 1 3 2 4 1 Positive Terminal 2 Negative Terminal 3 Surge Ground Terminal 4 Braided Ground Cable Figure 2 7 Terminal Block Wiring Single DC Power Supply Inputs 3 Connect the negative wire from the power source to the negative terminal on the terminal block RUGGEDCOM RS930L Installation Manual 02 2020 C79000 G8976 1034 06 15 ...

Страница 25: ... Terminal Block Wiring Dual DC Power Supply Inputs 5 Using a braided wire or other appropriate grounding wire connect the surge ground terminal to the chassis ground connection The surge ground terminal is used as the ground conductor for all surge and transient suppression circuitry in ternal to the unit 6 Connect the ground wire from the power source to the chassis groun terminal on the terminal...

Страница 26: ...nergized Console Port Connect a workstation directly to the RS232 serial console port to access the boot time control and RUGGEDCOM RS930L console interface The console port provides access to RUGGEDCOM RS930L s console interface IMPORTANT The serial console port is intended to be used only as a temporary connection during initial configuration or troubleshooting and should only be used in a safe ...

Страница 27: ...net Ports Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM RS930L console and Web interfaces via the device s IP address The factory default IP address for the RUGGEDCOM RS930L is https 192 168 0 1 For more information about available ports refer to Communication Ports Page 19 3 2 Configuring the Device Once the device is installed and conne...

Страница 28: ...Figure 4 1 Port Assignment Port Type 1 to 6 Copper Ethernet Ports 10 100Base TX 7 and 9 EoVDSL Ports 4 1 Copper Ethernet Ports The RUGGEDCOM RS930L supports multiple 10 100Base TX Ethernet ports that allow connection to standard Category 5 CAT 5 shielded or unshielded twisted pair cables with RJ45 male connectors RUGGEDCOM RS930L Installation Manual 02 2020 C79000 G8976 1034 06 19 ...

Страница 29: ...y LED Figure 4 2 RJ45 Port LEDs LED State Description Yellow The port is op erating at 100 Mbps Speed Off The port is op erating at 10 Mbps Yellow Solid Link estab lished Yellow Blink ing Link activity Link Activity Off No link detect ed Pin Out The following is the pin out for the RJ45 male connectors 1 8 Figure 4 3 RJ45 Ethernet Port Pin Config uration Pin Name Description 1 RX Receive Data 2 RX...

Страница 30: ...distances up to 5 km 3 1 mi Universal and Long Reach EoVDSL ports are physically indistinguishable from each other However the port type can be determined either from the order code or through the RUGGEDCOM RS930L user interface EoVDSL ports can be connected using RJ11 male connectors IMPORTANT Universal and Long Reach EoVDSL ports master or slave must be connected to EoVDSL ports slave or master ...

Страница 31: ... way of reducing both magnetic and capacitive in terference as they reduce the magnetic loop area to nearly zero and maintain a consistent distribution of capacitances to both ground and other sources There fore make sure twisting is consistent throughout the cable length Open leads also known as bridged taps or drop lines along the length of the ca ble will cause an impedance mismatch and result ...

Страница 32: ...lect the best bit rate based on the current line conditions Manual Mode In Manual Mode the user can select one of the speed settings and the device will only attempt to attain the set speed If the line conditions degrade reducing the SNR or Signal to Noise Ratio but the de vice is able to maintain the link an alarm will be triggered to notify the user of the reduced SNR By configuring the Rescan M...

Страница 33: ...297 ft 25 0 9 km 2953 ft 20 1 0 km 3280 ft 15 1 3 km 4265 ft 10 1 7 km 5577 ft 5 2 0 km 6562 ft 2 5 2 5 km 8202 ft 1 2 Long Reach EoVDSL Performance Characteristics On No 24 AWG Polyethylene Insulated Cable PIC twisted pair wiring the following performance is typical with Long Reach EoVDSL Distance km Distance ft Downstream Mas ter to Slave Mbps Upstream Slave to Master Mbps 0 50 1600 40 20 1 00 3...

Страница 34: ...100 VAC 240 VAC 3 15 A T 4 kVAC 10 W 24 12 VDC 24 VDC 3 15 A T 1 5 kVDC 10 W 48 37 VDC 72 VDC 3 15 A T 1 5 kVDC 10 W a T denotes time delay fuse b Power consumption varies based on configuration Non Hazardous Environments Input Voltage Power Sup ply Type Minimum Maximum Internal Fuse Rating a Isolation Maximum Power Con sumption b 88 VDC 300 VDC 3 15 A T 4 kVAC 10 W HI 85 VAC 264 VAC 3 15 A T 5 5 ...

Страница 35: ...Supported Networking Standards Standard 10 Mbps Ports 100 Mbps Ports 1000 Mbps Ports Description IEEE 802 1D ü ü ü MAC Bridges IEEE 802 1p ü ü ü Priority Levels IEEE 802 1Q ü ü ü VLAN Virtual LAN Tagging IEEE 802 3ab ü 1000Base Tx IEEE 802 3x ü ü ü Full Duplex Operation IEEE 802 3z ü 1000Base LX 5 4 Copper Ethernet Port Specifications The following details the specifications for copper Ethernet po...

Страница 36: ...mental con ditions Ambient Operating Tempera ture a 40 to 85 C 40 to 185 F Ambient Storage Temperature 40 to 85 C 40 to 185 F Ambient Relative Humidity b 5 to 95 Maximum Altitude 2000 m 6562 ft a Measured from a 30 cm 12 in radius surrounding the center of the enclosure b Non condensing 5 6 Mechanical Specifications Weight 1 2 kg 2 7 lbs Enclosure 20 AWG Galvanized Steel 5 7 Dimension Drawings Not...

Страница 37: ...Technical Specifications 5 7 Dimension Drawings 99 06 187 96 168 66 65 3 116 59 7 87 Figure 5 1 Overall Dimensions 28 RUGGEDCOM RS930L Installation Manual 02 2020 C79000 G8976 1034 06 ...

Страница 38: ...cal Specifications 5 7 Dimension Drawings 13 64 101 6 11 2 78 74 120 65 194 06 83 20 183 90 Figure 5 2 Panel and DIN Rail Mount Dimensions RUGGEDCOM RS930L Installation Manual 02 2020 C79000 G8976 1034 06 29 ...

Страница 39: ...Technical Specifications 5 7 Dimension Drawings 30 RUGGEDCOM RS930L Installation Manual 02 2020 C79000 G8976 1034 06 ...

Страница 40: ...Safety Part 1 General Requirements CAN CSA C22 2 No 0 M91 General Requirements Canadian Electrical Code Part II CAN CSA C22 2 No 142 M1987 Process Control Equipment Industrial Products CAN CSA C22 2 No 213 16 Non Incendive Electrical Equipment for Use in Class I and II Division 2 and Class III Divisions 1 and 2 Hazardous Classified Locations Bi National Standard with ANSI ISA 12 12 01 2016 UL 916 ...

Страница 41: ...n expense IMPORTANT Changes or modifications not expressly approved by the party responsible for com pliance could void the user s authority to operate this device 6 1 3 FDA CDRH This device meets the requirements of the following U S Food and Drug Administra tion FDA standard Title 21 Code of Federal Regulations CFR Chapter I Sub chapter J Radiolog ical Health 6 1 4 ISED This device is declared b...

Страница 42: ...mbol to indicate compliance when sold in the Australian region A copy of the Declaration of Conformity is available via Siemens Industry Online Sup port at https support industry siemens com cs ww en view 89855782 6 1 7 RoHS This device is declared by Siemens AG to meet the requirements of the following Ro HS Restriction of Hazardous Substances directives for the restricted use of certain hazardou...

Страница 43: ...und 2 kV 4 DC Pow er Ports 2 kV Line to Ground 1 kV Line to Line 3 IEC 61000 4 5 Surge AC Pow er Ports 4 kV Line to Ground 2 kV Line to Line 4 Signal Ports 10 V 3 DC Pow er Ports 10 V 3 AC Pow er Ports 10 V 3 IEC 61000 4 6 Induced Conducted RFI Earth Ground Ports 10 V 3 IEC 61000 4 8 Magnetic Field Enclo sure Ports 40 A m Continuous 1000 A m for 1 s IEC 61000 4 11 Voltage Dips and Interrupts AC Po...

Страница 44: ...C Pow er Ports 5 kV EMC Immunity Type Tests per IEEE 1613 Note The RUGGEDCOM RS930L meets Class 2 requirements for an all fiber configuration and Class 1 requirements for copper ports Class 1 allows for temporary communica tion loss while Class 2 requires error free and interrupted communications Description Test Levels Enclosure Contact 8 kV ESD Enclosure Air 15 kV Radiated RFI Enclosure Ports 35...

Страница 45: ... Tests Test Description Test Levels Severity Levels IEC 60068 2 1 Cold Temperature Test Ad 40 C 40 F 16 Hours IEC 60068 2 2 Dry Heat Test Bd 85 C 185 F 16 Hours IEC 60068 2 30 Humidity Damp Heat Cyclic Test Db 95 Non Con densing 55 C 131 F 6 Cycles IEC 60255 21 1 Vibration 2 g 10 to 150 Hz Class 2 IEC 60255 21 2 Shock 30 g 11 ms Class 2 36 RUGGEDCOM RS930L Installation Manual 02 2020 C79000 G8976 ...

Страница 46: ...ttps www siemens com ruggedcom Industry Online Support service and support https support industry siemens com Industry Mall https mall industry siemens com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY ...