Страница 2: ...ed Ethernet Switches RUGGEDCOM RS910L Installation Manual Preface Introduction 1 Installing the Device 2 Device Management 3 Communication Ports 4 Technical Specifications 5 Certification 6 04 2022 C79000 G8976 1030 10 ...

Страница 3: ...those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper Use of Siemens Products Note the following WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation If products and components from other manufacturers are used the...

Страница 4: ... Unpacking the Device 8 2 3 Installing the Device in Hazardous Locations 8 2 4 Mounting the Device 9 2 4 1 Mounting the Device on a DIN Rail 10 2 4 2 Mounting the Device to a Panel 11 2 5 Connecting the Failsafe Alarm Relay 12 2 6 Connecting Power 13 2 6 1 Connecting High AC DC Power 14 2 6 2 Connecting Low DC Power 16 3 Device Management 19 3 1 Connecting to the Device 19 3 2 Configuring the Devi...

Страница 5: ...5 Fiber Optic Ethernet Port Specifications 31 5 6 Serial Port Specifications 32 5 7 Operating Environment 32 5 8 Mechanical Specifications 33 5 9 Dimension Drawings 33 6 Certification 35 6 1 Approvals 35 6 1 1 CSA 35 6 1 2 FCC 36 6 1 3 FDA CDRH 36 6 1 4 ISED 36 6 1 5 TÜV SÜD 36 6 1 6 ISO 37 6 1 7 RoHS 37 6 1 8 Other Approvals 37 6 2 EMC and Environmental Type Tests 37 iv RUGGEDCOM RS910L Installat...

Страница 6: ...37222 SIMATIC NET Glossary The SIMATIC NET Glossary describes special terms that may be used in this document The glossary is available online via Siemens Industry Online Support SIOS at https support industry siemens com cs ww en view 50305045 Accessing Documentation The latest user documentation for RUGGEDCOM RS910L is available online at https support industry siemens com To request or inquire ...

Страница 7: ...s customer service representative Training Siemens offers a wide range of educational services ranging from in house training of standard courses on networking Ethernet switches and routers to on site customized courses tailored to the customer s needs experience and application Siemens Educational Services team thrives on providing our customers with the essential practical skills to make sure us...

Страница 8: ...s and manuals Submit SRs or check on the status of an existing SR Contact a local Siemens representative from Sales Technical Support Training etc Ask questions or share knowledge with fellow Siemens customers and the support community Contacting Siemens Address Siemens Canada Ltd Digital Industries Process Automation 300 Applewood Crescent Concord Ontario Canada L4K 5C7 Telephone Toll free 1 888 ...

Страница 9: ...Preface Contacting Siemens viii RUGGEDCOM RS910L Installation Manual 04 2022 C79000 G8976 1030 10 ...

Страница 10: ... on plant floors and curb side traffic control cabinets An operating temperature range of 40 to 85 C 40 to 185 F coupled with hazardous location certification Class I Division 2 optional conformal coating and a galvanized steel enclosure allows the RUGGEDCOM RS910L to be placed in almost any location The RUGGEDCOM RS910L can be mounted on a DIN rail or panel for efficient use of cabinet space The ...

Страница 11: ...bient operating temperature no fans 20 AWG Galvanized Steel DIN or panel mounting options provide secure mechanical reliability Optional Conformal coated printed circuit boards Power Supply Fully integrated power supply Universal high voltage range 125 250 VDC or 100 240 VAC Hazardous Environments 88 300 VDC or 85 264 VAC Non Hazardous Environments Dual LO DC inputs 24 or 48 VDC Terminal blocks fo...

Страница 12: ...nnecting to the device via the serial console port refer to Connecting to the Device Page 19 Communication Ports Communication ports in general receive and transmit data as well as provide access to the RUGGEDCOM ROS Web interface For more information about the various ports available refer to Communication Ports Page 21 Failsafe Alarm Relay Latches to default state when a power disruption or othe...

Страница 13: ...ance by a third party make sure it has been fully decommissioned For more information refer to the associated Configuration Manual Recycling and Disposal For environmentally friendly recycling and disposal of this device and related accessories contact a facility certified to dispose of waste electrical and electronic equipment Recycling and disposal must be done in accordance with local regulatio...

Страница 14: ...ditions Distance m Cable Type Wavelength nm Modal Bandwidth MHz km 100Base FX 1000Base SX 10GBase SR 850 200 275 33 OM1 62 5 125 1300 500 2000 850 500 550 82 OM2 50 125 1300 500 2000 850 1500 550 300 OM3 50 125 a 1300 500 2000 850 3500 550 400 OM4 50 125 a 1300 500 2000 a Laser optimized RUGGEDCOM RS910L Installation Manual 04 2022 C79000 G8976 1030 10 5 ...

Страница 15: ...Introduction 1 5 1 Supported Fiber Optic Cables 6 RUGGEDCOM RS910L Installation Manual 04 2022 C79000 G8976 1030 10 ...

Страница 16: ...iation exposure CAUTION Burn hazard risk of personal injury The surface of the device may be hot during operation or as a result of the ambient air temperature Wear appropriate personal protective equipment and use caution when working with or around the device NOTICE This product contains no user serviceable parts Attempted service by unauthorized personnel shall render all warranties null and vo...

Страница 17: ...d the device to safety Earth 5 Connect the device to the network 6 Configure the device 2 2 Unpacking the Device When unpacking the device do the following 1 Inspect the package for damage before opening it 2 Visually inspect each item in the package for any physical damage 3 Verify all items are included Note If any item is missing or damaged contact Siemens for assistance 2 3 Installing the Devi...

Страница 18: ...ot disconnect or open equipment unless power has been switched off or the area is known to be non hazardous NOTICE Substitution of the components may impair suitability for Class I Division 2 2 4 Mounting the Device The RUGGEDCOM RS910L is designed for maximum mounting and display flexibility It can be equipped with adapters that allow it to be attached to a DIN rail or panel Note Heat generated b...

Страница 19: ...ce to a DIN rail do the following 1 Hook the top teeth of the adapter onto the DIN rail Note The adapter features a sliding release with a slot at the bottom for a flathead screwdriver 1 2 3 2 1 1 1 DIN Rail 2 DIN Rail Adapter Figure 2 1 Mounting the Device to a DIN Rail 2 Insert a flathead screwdriver into the slot of the sliding release and move it down 3 Push the device against the bottom of th...

Страница 20: ...l 2 Swing the bottom of the device away from the DIN rail 3 Lift the device off the DIN rail 2 4 2 Mounting the Device to a Panel For panel installations the RUGGEDCOM RS910L can be equipped with panel adapters on the top and bottom of the chassis The adapters allow the device to be attached to a panel using screws To mount the device to a panel do the following 1 Prepare mounting holes in the pan...

Страница 21: ...s powered and there are no active alarms If the device is not powered or if an active alarm is configured the relay opens the NO contact and closes the NC Normally Closed contact Note Control of the failsafe relay output is configurable through RUGGEDCOM RS910L One common application for this relay is to signal an alarm if a power failure occurs For more information refer to the RUGGEDCOM ROS Conf...

Страница 22: ... For 125 250 VDC rated equipment an appropriately rated DC circuit breaker must be installed Use minimum 16 gage copper wiring when connecting terminal blocks Equipment must be installed according to applicable local wiring codes and standards All line to ground transient energy is shunted to the Surge Ground terminal In cases where users require the inputs to be isolated from ground remove the gr...

Страница 23: ...l hazard risk of damage to equipment Before testing the dielectric strength HIPOT in the field remove the braided ground cable connected to the surge ground terminal and chassis ground This cable connects transient suppression circuitry to chassis ground and must be removed in order to avoid damage to transient suppression circuitry during testing Note Torque all terminal connections to 0 6 N m 5 ...

Страница 24: ...om the power source to the positive live L terminal on the terminal block 4 1 2 3 1 Positive Live L Terminal 2 Negative Neutral N Terminal 3 Surge Ground Terminal 4 Braided Ground Cable Figure 2 5 Terminal Block Wiring RUGGEDCOM RS910L Installation Manual 04 2022 C79000 G8976 1030 10 15 ...

Страница 25: ...om the power source to the chassis groun terminal on the terminal block 2 6 2 Connecting Low DC Power RUGGEDCOM RS910L s equipped with 24 or 48 V power supply inputs feature reverse polarity protection and dual power supply inputs allowing the device to accept redundant connections to a single DC power supply To connect a low DC power supply to the device do the following Note Torque all terminal ...

Страница 26: ...erminal block 1 3 2 4 1 Positive Terminal 2 Negative Terminal 3 Surge Ground Terminal 4 Braided Ground Cable Figure 2 7 Terminal Block Wiring Single DC Power Supply Inputs 3 Connect the negative wire from the power source to the negative terminal on the terminal block RUGGEDCOM RS910L Installation Manual 04 2022 C79000 G8976 1030 10 17 ...

Страница 27: ... Terminal Block Wiring Dual DC Power Supply Inputs 5 Using a braided wire or other appropriate grounding wire connect the surge ground terminal to the chassis ground connection The surge ground terminal is used as the ground conductor for all surge and transient suppression circuitry internal to the unit 6 Connect the ground wire from the power source to the chassis groun terminal on the terminal ...

Страница 28: ...not energized Console Port Connect a workstation directly to the RS232 serial console port to access the boot time control and RUGGEDCOM ROS console interface The console port provides access to RUGGEDCOM RS910L s console interface Note The serial console port is intended to be used only as a temporary connection during initial configuration or troubleshooting and should only be used in a safe are...

Страница 29: ...Ports Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM RS910L console and Web interfaces via the device s IP address The factory default IP address for the RUGGEDCOM RS910L is https 192 168 0 1 For more information about available ports refer to Communication Ports Page 21 3 2 Configuring the Device Once the device is installed and connected...

Страница 30: ...ssignment Port Type 1 and 2 Serial Ports 3 and 4 Copper 10 100Base TX or Fiber Optic 100Base FX Ethernet Ports 9 EoVDSL Port 4 1 Copper Ethernet Ports The RUGGEDCOM RS910L supports multiple 10 100Base TX Ethernet ports that allow connection to standard Category 5 CAT 5 shielded or unshielded twisted pair cables with RJ45 male connectors RUGGEDCOM RS910L Installation Manual 04 2022 C79000 G8976 103...

Страница 31: ...res a Speed and Link Activity LED that indicates the state of the port 1 2 1 Speed LED 2 Link Activity LED Figure 4 2 RJ45 Port LEDs LED State Description Yellow The port is operating at 100 Mbps Speed Off The port is operating at 10 Mbps Yellow Solid Link established Yellow Blinking Link activity Link Activity Off No link detected Pin Out The following is the pin out for the RJ45 male connectors ...

Страница 32: ...ubscriber Connector or ST Straight Tip connectors Make sure the Transmit Tx and Receive Rx connections of each port are properly connected and matched to establish a proper link Port Types 2 1 1 Tx Connector 2 Rx Connector Figure 4 4 MTRJ Port 2 1 1 Tx Connector 2 Rx Connector Figure 4 5 LC Port 2 1 1 Tx Connector 2 Rx Connector Figure 4 6 SC Port 2 1 1 Tx Connector 2 Rx Connector Figure 4 7 ST Po...

Страница 33: ...igher throughput connections spanning distances up to 2 5 km 1 6 mi Long Reach EoVDSL Long Reach EoVDSL ports are fixed as either Master or Slave but offer asymmetric data rates upstream and downstream up to 40 Mbps They are best suited for lower throughput connections spanning distances up to 5 km 3 1 mi Universal and Long Reach EoVDSL ports are physically indistinguishable from each other Howeve...

Страница 34: ... Not Connect 4 3 1 EoVDSL Wiring VDSL operates over 2 wire Category 3 CAT 3 or higher twisted pair wiring Other twisted pair wiring with similar characteristics may work although the performance will vary depending on the cable characteristics and distance When wiring EoVDSL ports note the following EoVDSL ports are designed to be used on private communications lines for point to point connections...

Страница 35: ...ts will already be fixed as Master or Slave Once configured and connected together each device will attempt to achieve the maximum speed based on the line length and conditions The RUGGEDCOM RS910L s Link Act LED may flash on and off several times before setting on a final link speed and declaring the port up For more information about configuring the RUGGEDCOM RS910L refer to the RUGGEDCOM ROS Co...

Страница 36: ...stance can support the speed setting the time to establish a link is typically 15 to 30 seconds Universal EoVDSL Performance Characteristics On No 24 AWG Polyethylene Insulated Cable PIC twisted pair wiring the following performance is typical with Universal EoVDSL Distance Downstream Upstream Mbps 0 5 km 1640 ft 35 0 6 km 1969 ft 30 0 7 km 2297 ft 25 0 9 km 2953 ft 20 1 0 km 3280 ft 15 1 3 km 426...

Страница 37: ... 4 3 3 EoVDSL Performance Distance km Distance ft Downstream Master to Slave Mbps Upstream Slave to Master Mbps 4 60 15100 1 2 0 54 5 00 16400 0 48 0 18 28 RUGGEDCOM RS910L Installation Manual 04 2022 C79000 G8976 1030 10 ...

Страница 38: ...00 VAC 240 VAC 3 15 A T 4 kVAC 10 W 24 12 VDC 24 VDC 3 15 A T 1 5 kVDC 10 W 48 37 VDC 72 VDC 3 15 A T 1 5 kVDC 10 W a T denotes time delay fuse b Power consumption varies based on configuration Non Hazardous Environments Input Voltage Power Supply Type Minimum Maximum Internal Fuse Rating a Isolation Maximum Power Consumption b 88 VDC 300 VDC 3 15 A T 4 kVAC 10 W HI 85 VAC 264 VAC 3 15 A T 5 5 kVD...

Страница 39: ...s for 1 minute 5 3 Supported Networking Standards The following networking standards are supported by RUGGEDCOM RS910L Standard 10 Mbps Ports 100 Mbps Ports 1000 Mbps Ports Notes IEEE 802 3x Full Duplex Operation IEEE 802 3z 1000Base LX IEEE 802 3ab 1000Base Tx IEEE 802 1D MAC Bridges IEEE 802 1Q VLAN Virtual LAN IEEE 802 1p Priority Levels 5 4 Copper Ethernet Port Specifications The following det...

Страница 40: ...ber quality and the number of patches and splices Consult a Siemens sales associate when determining maximum segment distances 10Base FL Fiber Optic Tx dBm Mode Connector Type Tx λ nm a Cable Type µm Minimum Maximum Rx Sensitivity dBm Rx Saturation dBm Distance km a Power Budget dB 62 5 125 850 16 9 18 MM ST 50 125 850 19 8 12 8 34 11 2 2 14 2 a Typical 100Base FX Fiber Optic Tx dBm Mode Connector...

Страница 41: ...S910L Copper Serial Ports Baud Rate 300 to 230 kbps Connector DB9 or RJ45 Isolation 2 5 kV Fiber Serial Ports Mode Multimode Connector ST Typical Distance km 5 Optical Wavelength nm 820 Cable Size 50 125 or 62 5 125 5 7 Operating Environment The RUGGEDCOM RS910L is rated to operate under the following environmental conditions Ambient Operating Temperature a 40 to 85 C 40 to 185 F Ambient Storage T...

Страница 42: ...ions Weight 1 2 kg 2 7 lbs Enclosure 20 AWG Galvanized Steel 5 9 Dimension Drawings Note All dimensions are in millimeters unless otherwise stated 99 06 187 96 168 66 65 3 116 59 7 87 Figure 5 1 Overall Dimensions RUGGEDCOM RS910L Installation Manual 04 2022 C79000 G8976 1030 10 33 ...

Страница 43: ... Specifications 5 9 Dimension Drawings 13 64 101 6 11 2 78 74 120 65 194 06 83 20 183 90 128 4 Figure 5 2 Panel and DIN Rail Mount Dimensions 34 RUGGEDCOM RS910L Installation Manual 04 2022 C79000 G8976 1030 10 ...

Страница 44: ...afety Part 1 General Requirements CAN CSA C22 2 No 0 M91 General Requirements Canadian Electrical Code Part II CAN CSA C22 2 No 142 M1987 Process Control Equipment Industrial Products CAN CSA C22 2 No 213 16 Non Incendive Electrical Equipment for Use in Class I and II Division 2 and Class III Divisions 1 and 2 Hazardous Classified Locations Bi National Standard with ANSI ISA 12 12 01 2016 UL 916 S...

Страница 45: ...se harmful interference in which case users will be required to correct the interference at their own expense Note Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this device 6 1 3 FDA CDRH This device meets the requirements of the following U S Food and Drug Administration FDA standard Title 21 Code of Federal Regu...

Страница 46: ...ectronic equipment China RoHS 2 Administrative Measure on the Control of Pollution Caused by Electronic Information Products A copy of the Material Declaration is available online at https support industry siemens com cs ww en view 109738831 6 1 8 Other Approvals This device meets the requirements of the following additional standards IEC 61000 6 2 Electromagnetic Compatibility EMC Part 6 2 Generi...

Страница 47: ... 61000 4 6 Induced Conducted RFI Earth Ground Ports 10 V 3 IEC 61000 4 8 Magnetic Field Enclosure Ports 40 A m Continuous 1000 A m for 1 s IEC 61000 4 11 Voltage Dips and Interrupts AC Power Ports 100 for 5 Periods 100 for 50 Periods Signal Ports 2 5 kV Common Mode 1 MHz 1 kV Differential Mode 1 MHz 3 DC Power Ports 2 5 kV Common Mode 1 MHz 1 kV Differential Mode 1 MHz 3 IEC 61000 4 12 Damped Osci...

Страница 48: ...t configurations Class 1 allows for temporary communication loss while Class 2 requires error free and interrupted communications Description Test Levels Enclosure Contact 8 kV ESD Enclosure Air 15 kV Radiated RFI Enclosure Ports 35 V m Signal Ports 4 kV 2 5 kHz DC Power Ports 4 kV AC Power Ports 4 kV Fast Transient Earth Ground Ports 4 kV Signal Ports 2 5 kV Common Mode 1 MHz DC Power Ports 2 5 k...

Страница 49: ...ld Temperature Test Ad 40 C 40 F 16 Hours IEC 60068 2 2 Dry Heat Test Bd 85 C 185 F 16 Hours IEC 60068 2 30 Humidity Damp Heat Cyclic Test Db 95 Non Condensing 55 C 131 F 6 Cycles IEC 60255 21 1 Vibration 2 g 10 to 150 Hz Class 2 IEC 60255 21 2 Shock 30 g 11 ms Class 2 40 RUGGEDCOM RS910L Installation Manual 04 2022 C79000 G8976 1030 10 ...

Страница 50: ...dustry Online Support service and support https support industry siemens com Industry Mall https mall industry siemens com Siemens Canada Ltd Digital Industries Process Automation 300 Applewood Crescent Concord Ontario L4K 4E5 Canada 2022 Siemens Canada Ltd Subject to change ...