background image

Preface

Contacting Siemens

Telephone

Call a local hotline center to submit a Support Request (SR). To locate a

local hotline center, visit 

https://w3.siemens.com/aspa_app/?lang=en

.

Mobile App

Install the Industry Online Support app by Siemens AG on any Android,

Apple iOS or Windows mobile device and be able to:
• Access Siemens' extensive library of support documentation,

including FAQs and manuals

• Submit SRs or check on the status of an existing SR
• Contact a local Siemens representative from Sales, Technical Support,

Training, etc.

• Ask questions or share knowledge with fellow Siemens customers

and the support community

Contacting Siemens

Address

Siemens Canada Ltd.
Digital Industries
Process Automation
300 Applewood Crescent
Concord, Ontario
Canada, L4K 5C7

Telephone

Toll-free: 1 888 264 0006
Tel: +1 905 856 5288
Fax: +1 905 856 1995

E-Mail

[email protected]

Web

https://www.siemens.com

RUGGEDCOM RS8000A

Installation Manual, 12/2021, C79000-G8976-1021-06

vii

Содержание SIMATIC NET RUGGEDCOM RS8000A

Страница 1: ...Edition 12 2021 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM RS8000A https www siemens com ruggedcom ...

Страница 2: ...d Ethernet Switches RUGGEDCOM RS8000A Installation Manual Preface Introduction 1 Installing the Device 2 Device Management 3 Communication Ports 4 Technical Specifications 5 Certification 6 12 2021 C79000 G8976 1021 06 ...

Страница 3: ...those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper Use of Siemens Products Note the following WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation If products and components from other manufacturers are used the...

Страница 4: ...l Procedure 8 2 2 Mounting the Device 8 2 2 1 Mounting the Device on a DIN Rail 9 2 2 2 Mounting the Device to a Rack 10 2 2 3 Mounting the Device to a Panel 12 2 3 Connecting the Failsafe Alarm Relay 12 2 4 Connecting Power 13 2 4 1 Connecting AC Power 14 2 4 2 Connecting DC Power 15 3 Device Management 17 3 1 Connecting to the Device 17 3 2 Configuring the Device 18 3 3 Resetting the Device 18 4...

Страница 5: ...pecifications 22 5 5 Operating Environment 22 5 6 Mechanical Specifications 23 5 7 Dimension Drawings 23 6 Certification 27 6 1 Approvals 27 6 1 1 CSA 27 6 1 2 European Union EU 27 6 1 3 FCC 28 6 1 4 ISO 28 6 1 5 RoHS 29 6 2 EMC and Environmental Type Tests 29 iv RUGGEDCOM RS8000A Installation Manual 12 2021 C79000 G8976 1021 06 ...

Страница 6: ...mens com cs ww en view 109737246 SIMATIC NET Glossary The SIMATIC NET Glossary describes special terms that may be used in this document The glossary is available online via Siemens Industry Online Support SIOS at https support industry siemens com cs ww en view 50305045 Accessing Documentation The latest user documentation for RUGGEDCOM RS8000A is available online at https support industry siemen...

Страница 7: ... customer service representative Training Siemens offers a wide range of educational services ranging from in house training of standard courses on networking Ethernet switches and routers to on site customized courses tailored to the customer s needs experience and application Siemens Educational Services team thrives on providing our customers with the essential practical skills to make sure use...

Страница 8: ... and manuals Submit SRs or check on the status of an existing SR Contact a local Siemens representative from Sales Technical Support Training etc Ask questions or share knowledge with fellow Siemens customers and the support community Contacting Siemens Address Siemens Canada Ltd Digital Industries Process Automation 300 Applewood Crescent Concord Ontario Canada L4K 5C7 Telephone Toll free 1 888 2...

Страница 9: ...Preface Contacting Siemens viii RUGGEDCOM RS8000A Installation Manual 12 2021 C79000 G8976 1021 06 ...

Страница 10: ...plementing fault tolerant ring and mesh network architectures The protocol has been optimized to support ring sizes of up to 160 switches and fault recovery times in the order of less than 5 ms per switch The RUGGEDCOM RS8000A s superior ruggedized design coupled with the Rugged Operating System ROS provides improved system reliability and advanced networking features making it ideally suited for ...

Страница 11: ...on and 56 bit encryption Management Tools Web based Telnet CLI management interfaces SNMP v1 v2 v3 56 bit encryption Remote Monitoring RMON Rich set of diagnostics with logging and alarms Universal Power Supply Options Universal high voltage range 88 300 VDC or 85 264 VAC Popular low voltage ranges 24 VDC 10 36 VDC 48 VDC 36 59 VDC Terminal blocks for reliable maintenance free connections CSA UL 6...

Страница 12: ... Green Device ready Off No power RESET Button Shuts down and restarts the device For more information refer to Resetting the Device Page 18 Port Status Indicator LEDs These LEDs indicate when serial ports are active LED State Meaning Solid Link detected Link Off No link detected Blinking Link activity receiving RX Off No link activity Blinking Link activity transmitting TX Off No link activity RUG...

Страница 13: ... to a panel 1 4 Decommissioning and Disposal Proper decommissioning and disposal of this device is important to prevent malicious users from obtaining proprietary information and to protect the environment Decommissioning This device may include sensitive proprietary data Before taking the device out of service either permanently or for maintenance by a third party make sure it has been fully deco...

Страница 14: ...ater than 2500 V during line to ground fault conditions 1 5 1 Supported Fiber Optic Cables The following fiber optic cable types are supported under the stated conditions Distance m Cable Type Wavelength nm Modal Bandwidth MHz km 100Base FX 1000Base SX 10GBase SR 850 200 275 33 OM1 62 5 125 1300 500 2000 850 500 550 82 OM2 50 125 1300 500 2000 850 1500 550 300 OM3 50 125 a 1300 500 2000 850 3500 5...

Страница 15: ...Introduction 1 5 1 Supported Fiber Optic Cables 6 RUGGEDCOM RS8000A Installation Manual 12 2021 C79000 G8976 1021 06 ...

Страница 16: ...ording to the specification Damaged parts can lead to Injury to personnel Loss of certification approvals Violation of EMC regulations Damage to the device or other components CAUTION Burn hazard risk of personal injury The surface of the device may be hot during operation or as a result of the ambient air temperature Wear appropriate personal protective equipment and use caution when working with...

Страница 17: ...ents For more information refer to Approvals Page 27 2 Mount the device 3 Connect the failsafe alarm relay 4 Connect power to the device and ground the device to safety Earth 5 Connect the device to the network 6 Configure the device 2 2 Mounting the Device The RUGGEDCOM RS8000A is designed for maximum mounting and display flexibility It can be equipped with connectors that allow it to be installe...

Страница 18: ...ce to a DIN rail do the following 1 Hook the top teeth of the adapter onto the DIN rail Note The adapter features a sliding release with a slot at the bottom for a flathead screwdriver 1 2 3 1 1 2 1 DIN Rail 2 Panel DIN Rail Adaptor Figure 2 1 Mounting the Device to a DIN Rail 2 Insert a flathead screwdriver into the slot of the sliding release and move it down 3 Push the device against the bottom...

Страница 19: ... down 1 3 2 1 2 1 1 DIN Rail 2 DIN Rail Adapter Figure 2 2 Removing the Device from a DIN Rail 2 Swing the bottom of the device away from the DIN rail 3 Lift the device off the DIN rail 2 2 2 Mounting the Device to a Rack To secure the device to a standard 48 cm 19 in rack do the following 1 Remove the four screws from the side of the device 10 RUGGEDCOM RS8000A Installation Manual 12 2021 C79000 ...

Страница 20: ...nd device assembly into the rack Note Since heat within the device is channelled to the enclosure it is recommended that 1 rack unit of space or 44 mm 1 75 in be kept empty above the device This allows a small amount of convectional airflow Forced airflow is not required However any increase in airflow will result in a reduction of ambient temperature and improve the long term reliability of all e...

Страница 21: ...cting the Failsafe Alarm Relay The failsafe relay can be configured to latch based on alarm conditions The NO Normally Open contact is closed when the unit is powered and there are no active alarms If the device is not powered or if an active alarm is configured the relay opens the NO contact and closes the NC Normally Closed contact Note Control of the failsafe relay output is configurable throug...

Страница 22: ...er supply IMPORTANT For 88 300 VDC rated equipment an appropriately rated circuit breaker must be installed For 100 240 VAC rated equipment an appropriately rated circuit breaker must be installed Use minimum 16 gage wiring when connecting terminal blocks A circuit breaker is not required for 12 24 or 48 VDC rated equipment Power input terminals have reverse polarity protection for 12 24 and 48 VD...

Страница 23: ...uring testing 1 Connect the positive wire from the power source to the positive hot H terminal on the terminal block 4 1 2 3 1 Positive Hot H Terminal 2 Negative Neutral N Terminal 3 Surge Ground Terminal 4 Braided Ground Cable Figure 2 6 Terminal Block Wiring 2 Connect the negative wire from the power source to the negative neutral N terminal on the terminal block 3 Using a braided wire or other ...

Страница 24: ... 2 Connecting DC Power To connect a high or low DC power supply to the device do the following NOTICE Electrical hazard risk of damage to equipment Before testing the dielectric strength HIPOT in the field remove the braided ground cable connected to the surge ground terminal and chassis ground This cable connects transient suppression circuitry to chassis ground and must be removed in order to av...

Страница 25: ...ing a braided wire or other appropriate grounding wire connect the surge ground terminal to the chassis ground connection The surge ground terminal is used as the ground conductor for all surge and transient suppression circuitry internal to the unit 4 Using a 6 ring tongue and 6 32 screw secure the ground terminal on the power source to the chassis ground terminal on the device Make sure the lug ...

Страница 26: ...nnections during initial configuration or troubleshooting The serial console port implements RS232 DCE Data Communication Equipment on a DB9 connector The following is the pin out for the port 5 9 6 1 Figure 3 1 Serial DB9 Console Port Pin Name Description 1 NC No Connection 2 TX Transmit Data 3 RX Receive Data 4 NC No Connection 5 GND Signal Ground 6 NC No Connection 7 NC No Connection 8 NC No Co...

Страница 27: ...ut configuring the device refer to the RUGGEDCOM RS8000A Configuration Manual associated with the installed software release 3 3 Resetting the Device The RUGGEDCOM RS8000A can be reset rebooted using the RESET button The RESET button is recessed and can only be reached using a pin or small screwdriver To reset the device quickly press and release the RESET button with a pin 18 RUGGEDCOM RS8000A In...

Страница 28: ...port type has a specific place in the RUGGEDCOM RS8000A chassis 1 2 3 1 Ports 1 to 2 2 Ports 3 to 4 3 Ports 5 to 8 Figure 4 1 Port Assignment Port Type 1 to 2 10 100Base TX 3 to 4 10Base FL 5 to 8 100Base FX 4 1 Copper Ethernet Ports The RUGGEDCOM RS8000A supports several 10 100Base TX Ethernet ports that allow connection to standard Category 5 CAT 5 unshielded twisted pair UTP cables with RJ45 ma...

Страница 29: ...t Port Specifications Page 21 4 2 Fiber Optic Ethernet Ports Fiber optic Ethernet ports are available with either MTRJ Mechanical Transfer Registered Jack or LC Lucent Connector connectors Make sure the Transmit Tx and Receive Rx connections of each port are properly connected and matched to establish a proper link 2 1 1 Tx Connector 2 Rx Connector Figure 4 3 MTRJ Port 2 1 1 Tx Connector 2 Rx Conn...

Страница 30: ...C d 88 VDC 300 VDC 3 15 A T HI 110 230 VAC d 85 VAC 265 VAC 3 15 A T 15 W a F denotes fast acting fuse b T denotes time delay fuse c Power consumption varies based on configuration 10 100Base TX ports consume roughly 1 W less than fiber optic ports d This is the same power supply for both AC and DC 5 2 Failsafe Relay Specifications Voltage Current 30 VAC 0 3 A 30 VDC 1 A 80 VDC 0 3 A 5 3 Copper Et...

Страница 31: ...Bm Rx Sensitivity dBm Rx Saturation dBm Distance typ km Power Budget dB 62 5 125 850 16 9 34 18 MM ST 50 125 820 16 5 10 6 34 4 11 2 2 21 a MM Multi Mode SM Single Mode Fast Ethernet 100 Mbps Optical Specifications Mode a Connector Type Cable Type μm Tx λ typ nm Tx min dBm Tx max dBm Rx Sensitivity dBm Rx Saturation dBm Distance typ km Power Budget dB 50 125 1310 16 11 33 5 11 17 MM MTRJ 62 5 125 ...

Страница 32: ... cm radius surrounding the center of the enclosure b Non condensing 5 6 Mechanical Specifications Weight 2 25 kg 5 lbs Ingress Protection IP30 Enclosure 18 AWG Galvanized Steel 5 7 Dimension Drawings Note All dimensions are in millimeters unless otherwise stated RUGGEDCOM RS8000A Installation Manual 12 2021 C79000 G8976 1021 06 23 ...

Страница 33: ...tions 5 7 Dimension Drawings 248 9 200 3 172 2 49 3 Figure 5 1 Overall Dimensions 479 4 464 5 50 6 66 7 6 1 18 8 34 7 Figure 5 2 Rack Mount Dimensions 24 RUGGEDCOM RS8000A Installation Manual 12 2021 C79000 G8976 1021 06 ...

Страница 34: ...Technical Specifications 5 7 Dimension Drawings 274 3 264 2 101 6 63 8 61 8 Figure 5 3 Panel and Din Rail Mount Dimensions RUGGEDCOM RS8000A Installation Manual 12 2021 C79000 G8976 1021 06 25 ...

Страница 35: ...Technical Specifications 5 7 Dimension Drawings 26 RUGGEDCOM RS8000A Installation Manual 12 2021 C79000 G8976 1021 06 ...

Страница 36: ...Equipment Safety Part 1 General Requirements The Certificate Body CB test certificate is available on SIOS at https support industry siemens com cs us en view 109794219 6 1 2 European Union EU This device is declared by Siemens Canada Ltd to comply with essential requirements and other relevant provisions of the following EU directives EN 62368 1 Information Technology Equipment Safety Part 1 Gene...

Страница 37: ... the equipment is operated in a commercial environment This device generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to correct the interferen...

Страница 38: ...ironmental tests IEC 61850 3 Type Tests Test Description Test Levels Severity Levels Enclosure Contact 8 kV 4 IEC 61000 4 2 ESD Enclosure Air 15 kV 4 IEC 61000 4 3 Radiated RFI Enclosure ports 20 V m x Signal ports 4 kV 2 5 kHz x DC Power ports 4 kV 4 AC Power ports 4 kV 4 IEC 61000 4 4 Burst Fast Transient Earth ground ports 4 kV 4 Signal ports 4 kV line to earth 2 kV line to line 4 DC Power port...

Страница 39: ... 4 17 Ripple on DC Power Supply DC Power ports 10 3 Signal ports 2 kVAC Fail Safe Relay output DC Power ports 1 5 kVDC Dielectric Strength AC Power ports 2 kVDC Signal ports 5 kV Fail Safe Relay Output DC Power ports 5 kV IEC 60255 5 HV Impulse AC Power ports 5 kV IEEE 1613 C37 90 x EMC Immunity Type Tests Note RUGGEDCOM products meet Class 1 requirements for copper Ethernet configurations and Cla...

Страница 40: ...V Impulse AC Power ports 5 kV Signal ports 2 kVAC Failsafe Relay DC Power ports 1 5 kVDC C37 90 6 Dielectric Strength AC Power ports 2 kVAC Environmental Type Tests Test Description Test Levels Severity Levels IEC 60068 2 1 Cold Temperature Test Ad 40 C 40 F 16 Hours IEC 60068 2 2 Dry Heat Test Bd 85 C 185 F 16 Hours IEC 60068 2 30 Humidity Damp Heat Cyclic Test Db 95 non condensing 55 C 131 F 6 c...

Страница 41: ...Certification 6 2 EMC and Environmental Type Tests 32 RUGGEDCOM RS8000A Installation Manual 12 2021 C79000 G8976 1021 06 ...

Страница 42: ...dustry Online Support service and support https support industry siemens com Industry Mall https mall industry siemens com Siemens Canada Ltd Digital Industries Process Automation 300 Applewood Crescent Concord Ontario L4K 4E5 Canada 2021 Siemens Canada Ltd Subject to change ...

Отзывы: