Installing the Device
2.7.1 Connecting AC Power
• For 125/230 VAC rated equipment, an appropriately rated AC circuit breaker
must be installed.
• For 125/250 VDC rated equipment, an appropriately rated DC circuit breaker
must be installed.
• It is recommended to provide a separate circuit breaker for each power module
module.
• Equipment must be installed according to applicable local wiring codes and
standards.
2.7.1
Connecting AC Power
To connect AC power to the device, do the following:
DANGER
Electrocution hazard – risk of death, serious personal injury and/or damage to
the device
Make sure the supplied cover is always installed over high voltage screw-type
terminal blocks.
NOTICE
Electrical hazard – risk of damage to equipment
Do not connect AC power cables to a DC power supply terminal block. Damage to
the power supply may occur.
Note
The terminal block is installed using Philips screws and compression plates, allowing
either bare wire connections or crimped terminal lugs. Use #6 size ring lugs for
secure, reliable screws, which must be removed to make connections.