Installing the Device
2.4 Installing the Chassis Ground Connection
2
Adapter
Figure 2.2
Panel Mounting
2. Install the supplied screws to secure the adapters to the panel. Make sure the
screws are torqued to 2 ± 0.1 N·m (18 ± 1 lbf-in)
2.4
Installing the Chassis Ground Connection
If the ground terminal on the power supply module(s) is not connected to safety
Earth, a connection must be provided from the chassis ground terminal on the
RUGGEDCOM MX5000 chassis.
IMPORTANT
If the ground terminal on the power supply module(s)
is
connected to safety Earth,
a connection from the chassis ground terminal is not required.
1. Position the grounding cable and external tooth lock washer on the
RUGGEDCOM MX5000.
3
2
1
1
External Tooth Lock Washer
2
#8-32×5/16" Pan Head Screw
3
Grounding Cable
Figure 2.3
Chassis Ground Cable Assembly
RUGGEDCOM MX5000
Installation Manual, 01/2021, C79000-G8976-1059-13
13