Introduction
1.2 Description
Universal Power Supply Options
• Fully integrated, dual-redundant (optional) power supplies
• Universal high-voltage range: 88-300 VDC or 85-264 VAC
• Popular low voltage ranges: 24 VDC (10-36 VDC), 48 VDC (36-72 VDC)
• Screw or pluggable terminal blocks for reliable, maintenance-free connections
• CSA/UL 60950-1 safety approved to 85 °C (185 °F)
1.2
Description
The RUGGEDCOM M2200 features various ports, controls and indicator LEDs on the
display panel for connecting, configuring and troubleshooting the device. The dis-
play panel can be located on the rear, front or top of the device, depending on the
mounting configuration.
3
4
2
1
5
7
6
1
Fiber or Copper Ethernet Ports
2
Port Status Indicator LEDs
3
Mode Button
4
RS-232 Serial Console Port (RJ45)
5
Display Mode Indicator LEDs
6
Alarm Indicator LED
7
Power Module Indicator LEDs
Figure 1.1
RUGGEDCOM M2200
Communication Ports
Ports for communicating with other devices or accessing the
RUGGEDCOM RUGGEDCOM M2200 operating system are described
.
Port Status Indicator LEDs
Port status indicator LEDs indicate the operational status of each
port, dependent on the currently selected mode.
Mode
Color/State
Description
Green (Solid)
Link detected
Green (Blinking)
Link activity
Status
Off
No link detected
Green
Full duplex mode
Orange
Half duplex mode
Duplex
Off
No link detected
2
RUGGEDCOM M2200
Installation Manual, 03/2020, C79000-G8976-1044-16