Performance data
2.5 PROFINET IO characteristic data
CP 343-1
20
Manual, 12/2018,
C79000−G8976−C201
-08
Characteristic
Explanation / values
•
Transfer is not confirmed
The transfer of UDP frames is unconfirmed, in
other words the loss of messages is not detected
or displayed by the send block (AG_SEND).
•
No receipt of UDP broadcast
To avoid communications overload of the CP due
to high broadcast load, the CP does not allow
receipt of UDP broadcasts.
•
UDP frame buffering
Size of the frame buffer with buffering enabled: 2
Kbytes
Note:
Following a buffer overflow, newly arriving frames
are discarded.
Execution times of the FCs AG_SEND / AG_RECV
The execution time required to process the FC blocks (AG_SEND, AG_RECV) required on
the S7-300 / C7-300 CPU is decisive for the calculation of the CPU cycle times (OB1) for
SEND/RECEIVE connections.
Note
Measurements of transmission and reaction times in Ethernet, PROFIBUS and PROFINET
networks for a series of configurations can be found on the Internet at the following address:
25209605 (
http://support.automation.siemens.com/WW/vi
2.5
PROFINET IO characteristic data
Possible modes with PROFINET IO
In PROFINET IO, the CP can operate as a PROFINET IO device or as a PROFINET IO
controller.
Configuration limits of the CP as a PROFINET IO controller
The CP supports the following maximum configuration as a PROFINET IO controller:
Table 2- 5
Configuration limits of the CP as a PROFINET IO controller
Characteristic
Explanation / values
Number of operable PROFINET IO devices
32 *), **)
Size of the input area over all PROFINET IO devices ***)
1024 bytes max.
Size of the output area over all PROFINET IO devices
1024 bytes max.
Size of the IO data area per submodule of a module in an IO
device
Содержание SIMATIC NET CP 343-1
Страница 8: ...Preface CP 343 1 8 Manual 12 2018 C79000 G8976 C201 08 ...
Страница 30: ...Requirements for use 3 3 Programming CP 343 1 30 Manual 12 2018 C79000 G8976 C201 08 ...
Страница 34: ...LEDs CP 343 1 34 Manual 12 2018 C79000 G8976 C201 08 ...
Страница 64: ...Service and maintenance 7 4 Replacing a module CP 343 1 64 Manual 12 2018 C79000 G8976 C201 08 ...
Страница 78: ...Index CP 343 1 78 Manual 12 2018 C79000 G8976 C201 08 ...