Connection
ANT793-8DP
C79000-G8974-C320-02, 01/2017
39
4
Connection
4.1
Notes on connecting up
WARNING
Danger due to lightning strikes
Antennas installed outdoors must be within the area covered by a lightning
protection system. Make sure that all conducting systems entering from outdoors
can be protected by a lightning protection potential equalization system.
When implementing your lightning protection concept, make sure you adhere to the
VDE 0182 or IEC 62305 standard.
Suitable lightning protectors are available in the range of accessories of SIMATIC
NET Industrial WLAN:
●
Lightning protection element LP798-1N (article number 6GK5798-2LP00-2AA6)
●
Lightning protection element LP798-2N (article number 6GK5798-2LP10-2AA6)
Note
We recommend that you use the maintenance-free lightning protector LP798-2N.
Exception:
When there is also DC power is supplied via the antenna cable. In this case, only the
lightning protector LP798-1N can be used.
WARNING
Danger due to lightning strikes
Installing this lightning protector between an antenna and a SCALANCE W700 is
not adequate protection against a lightning strike. The lightning protectors listed
above only work within the framework of a comprehensive lightning protection
concept. If you have questions, ask a qualified specialist company.
Содержание SIMATIC NET ANT793-8DP
Страница 1: ......
Страница 2: ......
Страница 3: ...1 Deutsch 3 English 25 ...
Страница 4: ......
Страница 25: ...Maßbilder ANT793 8DP C79000 G8974 C320 02 01 2017 23 Halterung Vorderansicht Die Maße sind in mm angegeben ...
Страница 32: ...Mounting ANT793 8DP 30 C79000 G8974 C320 02 01 2017 Overview Drilled holes Plugs Support Screws ...