Connection
6.5 Digital input/output
SCALANCE WxM766
60
Operating Instructions, 03/2022, C79000-G8976-C617-03
Rules for wiring
•
To wire the digital input/output, use a copper cable of category AWG18-16 or a cable
with a cross-section of 0.75 to 1.5 mm
2
.
•
Always wire the digital input/output in pairs.
•
The maximum permissible cable length is 3 m.
Position / Assignment
Example:
1
DI-
Ground
2
DO-
Ground
3
DO+
Switching signal
4
DI+
Input
5
NC
Not connected
If there is an adequate switching voltage at the digital input, the digital input is active
and the "DI" LED is lit.
The voltage applied to the "DI" contact is converted to a digital status by the device as
follows:
Voltage
Status
-30 to +3 V DC
0
+10 to +30 V DC
1
The digital output is a switch that switches the signal at +DO to -DO.
Содержание SIMATIC NET 6GK5766-1GE00-3DA0
Страница 8: ...Introduction SCALANCE WxM766 8 Operating Instructions 03 2022 C79000 G8976 C617 03 ...
Страница 10: ...Safety notices SCALANCE WxM766 10 Operating Instructions 03 2022 C79000 G8976 C617 03 ...
Страница 64: ...Connection 6 7 Replacing a CLP SCALANCE WxM766 64 Operating Instructions 03 2022 C79000 G8976 C617 03 ...
Страница 66: ...Maintenance and cleaning SCALANCE WxM766 66 Operating Instructions 03 2022 C79000 G8976 C617 03 ...
Страница 74: ...Technical specifications SCALANCE WxM766 74 Operating Instructions 03 2022 C79000 G8976 C617 03 ...
Страница 76: ...Dimension drawing SCALANCE WxM766 76 Operating Instructions 03 2022 C79000 G8976 C617 03 Side view ...
Страница 78: ...Dimension drawing SCALANCE WxM766 78 Operating Instructions 03 2022 C79000 G8976 C617 03 ...
Страница 80: ...Approvals SCALANCE WxM766 80 Operating Instructions 03 2022 C79000 G8976 C617 03 ...