Technical data
11.4 Technical specifications of ring light (external)
SIMATIC MV500
250
Operating Instructions, 03/2021, C79000-G8976-C494-05
11.4
Technical specifications of ring light (external)
Table 11- 4 Technical specifications of the external ring lights for SIMATIC MV500
6GF3400-0LT01-8DA1
6GF3400-0LT01-7BA1
Product type designation
External ring light MV400/MV500
Optical data
Lighting distance (max.)
3.0 m
Light color / wavelength
(relative luminosity 0.2 ... 1.0)
•
8DA1: Red / 625 nm
•
7BA1: Infrared / 850 nm
Flash mode
•
Duty cycle
•
40%
•
Max. exposure time
•
10 ms
Supply voltage, current consumption, power loss
Supply voltage
24 V DC (18 to 30 V DC)
Current consumption (at 24 V DC)
•
8DA1 (Red): 0.6 A
•
7BA1 (Infrared): 1.0 A
Permitted ambient conditions
Ambient temperature
•
During operation
•
0 … +50 °C
•
During transportation and storage
•
-30 … +80 °C
Relative humidity (max.)
95%
Degree of protection
IP67
Design, dimensions and weight
Dimensions (∅
× H)
142 × 42.5 mm
Weight
450 g