Technical specifications
9.3 Fail-safe mode
KP8, KP8F
86
Operating Instructions, 10/2010, A5E03284305-01
9.3
Fail-safe mode
KP8F internal
The block diagram of the KP8F:
,QSXWXQLW
&RQWUROOHU
%ODFNFKDQQHO
,QSXW
2XWSXW
3RZHUVXSSO\
The relevant values of the individual blocks are shown in the following.
Note
All values for the following data are based on the SN 29500:2005 and an ambient
temperature of 60 °C.
Input unit – 1oo1 mode
Parameter
Value
Comment
Hardware Fault Tolerance
0
–
Classification
A
–
Architecture
1oo1D
–
Failure mode
Detected
Undetected
Dangerous process value
5.50 FIT
0.34 FIT
Due to failures in the input circuit
Failure Mode Diagnostic
Detected
Undetected
No error signaling or no safe
values
0 FIT
0 FIT
Calculation according
IEC13849:2006 CAT4
Diagnostic Coverage
94.15 %
–
Diagnostic test interval
15 ms
Errors detected in each firmware
cycle
Safe Failure Fraction
99.19 %
–